Technical Data

HxWxL fl oorconstruction
HxWxL wallconstruction
Weight
Inlet
Collection in bag/container
Max Temp
Flow, max
Neg. pressure, max
Power consumption
Manual reverse pulse
fi lter cleaning
Fine fi lter polyester, area
Degree of separation
A fi ne fi lter, polyester (Part No 42025), is mounted in the
machine. A HEPA fi lter is available as optional equipment.
Soundlevel
Filter Cleaning with Reverse Pulse
Compressed air
Connection, hose
El connection

Description

The DC 3800 Stationary is a dust extractor suitable
for the extraction of dust, powders and chips and
also for cleaning.
The fi lter is cleaned with air pulse against the
fl ow of extracted air. This arrangement provides
for very effective cleaning while at the same time
giving long fi lter life.
The dust laden air is introduced into the units cyclone
where most of the dust is separated by the cyclonic
action of the air. This dust falls to the bottom of the

Installation

The machine should be equipped with a suitable
electrical starter and installed by a certifi ed electri-
cian. The unit should be equipped with a lockable
disconnect.
Assemble the fi lter unit. Mount it on the fl oor. Con-
nect the tubing to the inlet and outlet. Connect the
fi lter cleaning module to a compressed air supply
50 Hz/60 Hz
1400x400x860 mm
1440x400x790 mm
50 kg/50 kg
 50 mm/ 50 mm
kPa
20
30 l/40 l
130°/130°
260 m
/h/320 m
/h
3
3
28 kPa/30 kPa
2.2 kW/3 kW
10
1.8 m
1.8 m
2
> 99,9 %/> 99,9 %
<75 dB(A)/<75 dB(A)
4 l/s, 4 bar
6/8 mm
24 V DC, 12 W
cyclone where it is emptied into a plastic sack. The air
then passes through the fi ne fi lter and is exhausted
through the pump. HEPA fi ltration is available as an
option.
The vacuum is produced by an motor driven turbo-
pump. The turbopump is a regenerative blower where
a direct driven impeller rotates in the pump housing.
The tolerances of the unit are very small so that it is
possible to attain the highest effi ciency. Because the
pump compresses the air, it is natural that it becomes
hot while running.
of 4 l/s, 4 bars and a control voltage of 24 V DC,
12 W (which should be taken from the control box).
Connect the tubing system to the inlet and outlet of
the machine. Install and tighten a plastic sack under
the cyclone.
DC 3800 Stat - 10
Vacuum producer
capacity
DC 3800
2.5 kW 50 Hz
2
100
200
DC 3800 3.0 kW 60 Hz
300
400
500
m
3
/h
Part No 9443-A