Indicator Lamps; What Flashing Indicator Lamps Mean - 3M DMS 700 Série Guide De L'utilisateur

Table des Matières

Publicité

3M
Digital Media System 700 Series
Troubleshooting (continued)

Indicator Lamps

ATTENTION • When the interior portion has become overheated, for safety purposes, the power source is
automatically turned off, and the indicator lamps may also be turned off. In such a case, press the "•" (power
OFF) side of the main power switch and wait at least 45 minutes. After the unit has sufficiently cooled down,
please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.
Lighting and flashing of the power indicator, the lamp indicator, and the temp indicator have the meanings as
described in the table below. Please respond in accordance with the instructions within the table. If the same
indication is displayed after the treatment, or if an indication other than the following is displayed, please contact
your dealer or service company.

What Flashing Indicator Lamps Mean

Lamp
Power indicator
indicator
Lighting in orange Turned off
Flashing in green
Turned off
Lighting in green
Turned off
Flashing in orange Turned off
Blinking in red
Lighting or
Lighting in
blinking in red
red
Lighting or
Blinking in
blinking in red
red
© 3M 2007. All Rights Reserved.
Temp.
indicator
Description
Turned off
The unit is in a standby state. Please refer to the
"Power ON/OFF" section of this manual.
Turned off
The unit is warming up. Please wait.
Turned off
The unit is in an ON state. Ordinary operations may
be performed.
Turned off
The unit is cooling down. Please wait.
The unit is cooling down. A certain error has been
detected. Wait until the power indicator has finished
flashing, and then perform the proper response
measure using the item descriptions below as
reference.
Turned off
The projector lamp has not been properly fixed
(attached), the projector lamp does not light, and/or
there is a possibility that the interior portion has
become heated. Turn the power OFF and wait at least
20 minutes. After the unit has sufficiently cooled
down, please make confirmation of the following
items, and then turn the power ON again. If the
same indication is displayed, please change the lamp.
• Is there blockage of the air passage aperture?
• Is the air filter is dirty?
• Does the peripheral temperature exceed 35˚C?
Turned off
The lamp cover has not been properly fixed
(attached). Turn the power OFF and wait at least 45
minutes. After the unit has sufficiently cooled down,
please make confirmation of the attachment state of
the lamp and lamp cover, and then turn the power ON
again.
Troubleshooting