Télécharger Imprimer la page

Beko ÖWAMAT 8 Instructions De Montage Et De Service page 3

Masquer les pouces Voir aussi pour ÖWAMAT 8:

Publicité

Please check if your ÖWAMAT
to these instructions.
Application:
The ÖWAMAT
unit is designed for the treatment of de-
®
mulsifiable compressor condensates in compliance with
legal requirements. Your local "lower-level water authority"
needs to be notified about the operation of the oil-water
separator.
• Media / ambient temperature: +5...+60 °C
• ÖWAMAT
only suitable for stationary application
®
• ÖWAMAT
is not suitable for use in hazardous areas
®
Safety rules:
• It is absolutely essential to observe the present Instructions
for Installation and Operation.
Caution!
Oil-contaminated condensate!
Oil-contaminated condensate contains substances that
are hazardous both to health and the environment. These
substances may cause irritation or damage to the skin, eyes
and mucous linings. Oil-contaminated condensate must
not be allowed to get into the sewer system, water bodies
or the soil. Contaminated objects have to be cleaned or
disposed of according to the legal regulations.
The wastewater destined for indirect discharge must not exceed
a hydrocarbon concentration of 20 mg/l.
Please note that the national legal limit values for indirect dis-
charge may vary regionally.
Danger!
Compressed air!
Contact with quickly or suddenly escaping compressed air
or with bursting plant components carries a risk of serious
injury or death.
Only use pressure-resistant installation material!
Ensure that condensate cannot squirt or splash onto
persons or objects.
• Non-observance can result in injuries or damage to de-
vices! For the installation, the national regulations and
safety instructions in force also need to be observed!
• Only transport the ÖWAMAT
• Do not install the ÖWAMAT
• Protect the ÖWAMAT
against direct exposure to sunlight!
®
ÖWAMAT
8
®
type corresponds
®
unit when it is empty!
®
outdoors!
®
• In the case of installation in a room where there is a danger
of frost, a heating system has to be employed (optional)!
• Take measures to ensure that oil or untreated condensate
cannot enter the sewer system in the event of damage!
• Always screw the oil collector tightly to the preseparation tank
to make sure that oil cannot leak out!
• Do not fill any foreign liquid or substances into the presepara-
tion tank / ÖWAMAT
since this may impair the filter function!
®
• Only use original OEKOSORB
In the event of significant differences compared with the
speci fications of the general technical approval, e.g. the
employment of non-original filters, the approval no longer
covers the usability of the ÖWAMAT
individual approval of the responsible local authority will be
required.
Moreover, there will be no entitlement to the remedy of
defects within a 1-year period!
The operator's duty of care includes the following:
Installation, siting, maintenance, repair or cleaning:
These tasks have to be carried out by a specialist firm, as
required by law, unless the operator himself possesses the
necessary qualifications and entitlements.
It should further be realised that the statutory limits for indirect
clean-water discharge into the sewer system may be subject
to regional variations.
Caution!
Oil-contaminated condensate!
Oil-contaminated condensate contains substances that
are hazardous both to health and the environment. These
substances may cause irritation or damage to the skin, eyes
and mucous linings. Oil-contaminated condensate must
not be allowed to get into the sewer system, water bodies
or the soil. Contaminated objects have to be cleaned or
disposed of according to the legal regulations.
This work has to be documented in the operating manual.
The operating manual and maintenance reports must be
filed and presented to the responsible local authority if
requested.
Supervision:
The operator must ensure through constant monitoring
that the ÖWAMAT
oil-water separator is in a leaktight
®
condition and functioning correctly.
• Check the oil-water separator for leaks regularly!
• Check the outflowing clean water every week using the refer-
ence test kit!
• Always keep a spare OEKOSORB
Transport
Move the ÖWAMAT
suitable means of transportation.
replacement filter sets!
®
product. In such cases,
®
filter set!
®
only when empty and with
®
3

Publicité

loading