OPERATION
7. Turn gas control knob counterclockwise to ON.
8. Replace front access panel.
9. Turn on all electric power to the appliance.
10. Turn on power switch and:
a. After approximately 20 seconds the ignition sequence
should begin and light the pilot. If the water temperature
is below the setpoint the heating process will start.
b. Allow the Booster Water Heater to run until the burner
shuts down. The Booster Water Heater is now at its
setpoint, stabilized working temperature.
c. Run the dishmachine through at least two rinse cycles.
After the first rinse cycle, the burner should re-light and
remain lit until the water maintains 180°–185°F (82°–
85°C) output at 20 psi through the second cycle.
NOTE: If this test does not proceed as described, contact Hatco
Corporation or an authorized service agent for technical
assistance.
11. If the appliance will not operate, follow the "To Turn Off Gas
To Appliance" procedure in this section and call a service
technician or gas supplier.

MAINTENANCE

General

Gas Booster Water Heaters are designed for maximum durability
and performance with minimum maintenance.
ELECTRIC SHOCK HAZARD: Use only Genuine Hatco
Replacement Parts when service is required. Failure to use
Genuine Hatco Replacement Parts will void all warranties
and may subject operators of the equipment to hazardous
electrical voltage, resulting in electrical shock or burn.
Genuine Hatco Replacement Parts are specified to operate
safely in the environments in which they are used. Some
aftermarket or generic replacement parts do not have the
characteristics that will allow them to operate safely in
Hatco equipment.
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to fire, explosion,
electric shock, or burn.
ALWAYS turn OFF power at fused disconnect switch/circuit
breaker, shut off gas supply, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
This unit has no "user-serviceable" parts. If service
is required on this unit, contact an Authorized Hatco
Service Agent or contact the Hatco Service Department at
800-558-0607 or 414-671-6350.
Using or storing chlorine based products on or near the
Booster Water Heater may shorten the life of the unit and
void the product warranty.
NOTE: Refer to the REPLACEMENT PARTS LIST for exploded
views, part identification and location.
NOTE: Refer to the WIRING DIAGRAM for specific electrical
information.
WARNING
CAUTION
To Turn Off Gas To Appliance:
1. Turn off power switch on heater.
2. Turn off all electric power to the appliance if service is to be
performed.
3. Shut off external manual gas valve.
4. Remove front cover of heater for access to the control
compartment.
5. Turn gas control knob clockwise to OFF. Do not force.
6. Replace front access panel.
To avoid freezing water damage to the Booster Water
Heater when the outside temperature is below 32°F (0°C),
the unit must be left on and the venting must be protected
from migrating cold air.
1. Keep the area around the heater free and clear of debris
and flammable materials. Do not block air intakes or vents.
2. The recirculating water pump motor is permanently
lubricated and requires no other maintenance.
3. Visually observe and inspect the burner and pilot flame
every six months. When the burner is operating properly, a
clean blue flame will be visible. Depending on the condition
of the kitchen environment, the burner may need to be
cleaned of lint or grease-laden dust. If any problems are
apparent, discontinue use of the heater and contact the
Hatco Corporation or your authorized service agent.
Broad Blue Outer Flame
Light Blue Inner Cone
Slotted Burner Element
• The flame during full burn is a broad blue color. An inner
cone slightly lighter in color will also be visible.
• The flame should not be rising off of the face of
the burner element.
• Yellow tipped flames suggest a need for
adjustment or cleaning of the burner assembly.
4. Visually observe and inspect the heat exchanger and
exhaust blower fan. Depending on the condition of the
kitchen environment, the heat exchanger and fan may need
to be cleaned of lint or grease laden dust. If any problems
are apparent, discontinue use of the heater and contact the
Hatco Corporation or your authorized service agent.
5. Once a month, check and clean (if necessary) all air inlet
holes on the side or back of the unit.