Hatco Powermite PMG-100 Manuel D'installation Et D'utilisation page 10

Surchauffeur d'eau à gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Altitude Summary Publication Data for PMG Booster Water Heaters
Natural Gas
Altitude
Feet
0–2000
Meters
(0–610)
PMG-100
Approved Input
105000
Rate *
Suggested
#34DMS #34DMS #34DMS
Orifice Size †
GPH Capacity
1
De-Rate •
PMG-200
Approved Input
195000
Rate *
Suggested
#35DMS #36DMS #36DMS
Orifice Size †
GPH Capacity
1
De-Rate •
Liquid Propane Gas
Altitude
Feet
0–2000
Meters
(0–610)
PMG-100 LPG
Approved Input
105000
Rate *
Suggested
#50DMS #50DMS #50DMS
Orifice Size †
GPH Capacity
1
De-Rate •
PMG-200 LPG
Approved Input
195000
Rate *
Suggested
#50DMS #51DMS #51DMS
Orifice Size †
GPH Capacity
1
De-Rate •
* This is the maximum allowable BTU rate certified by CSA. These are to be verified by the qualified gas installer on site. Check
Heat Value with local Gas Utility.
† The first orifice size is the factory built unit. The next sizes are shown at the altitudes where a change is required to allow
pressure adjustments to the approved input rates.
• This is a de-rate multiplier to use when sizing a Hatco Gas Booster Water Heater for a given application. Multiply this number by
the GPH rating of the desired Booster Water Heater to ensure it will provide the required GPH capacity. This number also can
be divided into the required GPH capacity to find the adjusted GPH that corresponds with the GPH ratings of Hatco Gas Booster
Water Heaters.
2001–3000
3001–4000
4001–5000
(610–915)
(915–1220)
(1220–1525)
103363
101726
100089
#34DMS
0.98
0.97
0.95
171600
163800
156000
#37DMS
0.88
0.84
0.80
2001–3000
3001–4000
4001–5000
(610–915)
(915–1220)
(1220–1525)
102937
100874
98810
#50DMS
0.98
0.96
0.94
171600
163800
156000
#51DMS
0.88
0.84
0.80
5001–6000
6001–7000
7001–8000
(1525–1830)
(1830–2135)
(2135–2440)
98452
96815
95178
#34DMS
#34DMS
#34DMS
0.94
0.92
148200
140400
132600
#37DMS
#38DMS
#39DMS
0.76
0.72
5001–6000
6001–7000
7001–8000
(1525–1830)
(1830–2135)
(2135–2440)
96747
94684
92621
#50DMS
#50DMS
#50DMS
0.92
0.90
148200
140400
132600
#51DMS
#52DMS
#52DMS
0.76
0.72
10
English
8001–8500
8501–9500
(2440–2593)
(2593–2898)
94360
90585
#34DMS
#34DMS
0.91
0.90
0.86
128700
123552
#40DMS
#41DMS
0.86
0.66
0.63
8001–8500
8501–9500
(2440–2593)
(2593–2898)
91589
87925
#50DMS
#50DMS
0.88
0.87
0.84
128700
123552
#52DMS
#53DMS
0.86
0.66
0.63
PMG100200M-0222
9501–10500
(2898–3203)
86811
#34DMS
0.83
118404
#42DMS
0.61
9501–10500
(2898–3203)
84262
#50DMS
0.80
118404
#53DMS
0.61

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Powermite pmg-200