Télécharger Imprimer la page

Skytec 154.062 Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

During automatic play of a running light pattern, it is possible to switch off a particular
channel and to control that channel manually. Hold the BLIND button down while pressing the
flash button of the channel that you wish to switch off temporarily. To switch the channel on
again, proceed in the same way.
DIFFERENT FUNCTIONS FOR THE MIDI PROTOCOL
Switching on the MIDI input function:
1) Hold the RECORD/SHIFT button down.
2) Press three times the flash button no. 1 in the PRESET A section.
3) Release the buttons. The display shows now [Chl]
4) Select via one of the flash buttons 1 to 12 in section PRESET B the pattern to which you
wish to add the MIDI file.
Switching on the MIDI output function:
5) Hold the RECORD/SHIFT button down.
6) Press three times the flash button no. 2 in the PRESET A section.
1) Release the buttons. The display shows now [Ch0].
2) Select via one of the flash buttons 1 to 12 in section PRESET B the pattern from where you
wish to switch on the MIDI output function.
Switching off the MIDI in- and output functions
1) Hold the RECORD/SHIFT button down.
2) Press the REC/EXIT button once.
3) Release both buttons. The display show now 0.00.
Downloading a MIDI control file:
1) Hold the RECORD/SHIFT button down.
2) Press three times the flash button no. 3 in the PRESET A section.
3) Release both buttons. The display shows now [IN].
4) While downloading the data, all running light functions are temporarily switched off.
5) The control protocol downloads the data from address 55Hex under the file name
DC1224.bin.
Uploading a MIDI control file:
1) Hold the RECORD/SHIFT button down.
2) Press three times the flash button no. 4 in the PRESET A section.
3) Release both buttons. The display shows now [OUT].
4) While uploading the data, all running light functions are temporarily switched off.
5) The control protocol uploads the data to address 55Hex under the file name DC1224.bin.
TECHNICAL SPECIFICATIONS
-
Total control via a state-of-the-art microprocessor.
-
All stored data and running light programs are protected by a built-in battery.
-
Case in standard 19" rack dimensions.
-
Reversible DMX signal polarity.
-
MIDI input, output and through-connection.
-
4 pages with a capacity of 12 running light patterns each.
-
Power requirements 12-20 V=/500 mA.
-
DMX output via 3-pin DMX connector.
-
MIDI signal connection via 5-pin DIN connector.