Chapter 9 : REMOTE CONTROL PROGRAMMER'S GUIDE (continued)
9-4. COMMANDS AND RESPONSES TABLE (continued)
ASCII
RESPONSE
COMMAND
STATUS COMMANDS
U
UNIT
IL
ILD
ID
IFD
IP
IPS
IH
IHP
IV
IVP
IK
IST
II
IIN
IO
IOO
IF
IFA
XF
REFF
XT
REFT
COMMUNICATION PORT COMMANDS
ne
LANE
nr
LANR
ns
LANS
na
ADIP
nw
IPA_
nx
IPB_
ny
IPC_
nz
IPD_
np
PORT
nk
NTMK
nt
TCP
NOTE: * = command available on the OCTO-FADE
** = command available on the OCTO-LOGO
PAGE 38
COMMAND
DESCRIPTION
Measures unity in kHz.
This command allows to calculate the
input line frequency in Hz.
This command allows to calculate the
input frame frequency in Hz.
Input Sync. detection.
Sign of the horizontal input Sync.
Sign of the vertical input Sync.
Input Sync type detection.
Interlaced signal detection.
"Out of range" signal detection.
Standard input signal detection.
Standard of the reference input.
Frame frequency of the reference input Rd
Communication port selection
Reset of the LAN parameters.
Store the LAN parameters.
IP address and port selection (for
modification)
First byte of the address selected by the
na command.
Second byte of the address selected by
the na command.
Third byte of the address selected by the
na command.
Forth byte of the address selected by the
na command.
Number of the port (local or remote)
selected by the na command.
Netmask.
Protocol selection.
TYPE
MIN MAX
Rd
0
65535
Rd
0
65535
Rd
0
65535
Rd
0
1
0
1
Rd
Rd
0
1
Rd
0
3
0
1
Rd
Rd
0
1
0
27
Rd
0
27
Rd
0
65535 Value in Hz.
Rd/Wr
0
1
Rd/Wr
0
1
Rd/Wr
0
1
Rd/Wr
0
3
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
255
Rd/Wr
0
65500
Rd/Wr
0
24
Rd/Wr
0
1
™
™
& OCTO-FX
only.
™
™
& OCTO-FX
only.
VALUE
DESCRIPTION
Line frequency (in kHz) = (UNIT VALUE) ÷
(ILD VALUE).
Frame frequency (in Hz) = (Line frequency in
Hz) ÷ (IFD VALUE).
0 = not detected
1 = Sync. detected.
0 = negative
1 = positive.
0 = negative
1 = positive.
0 = H &V.
2 = SOG.
1 = Composite (TTL).
3 = Composite (ana)
0 = not interlaced
1 = interlaced.
0 = In range
1 = Out of range.
0 = no signal.
1 = not compatible.
2 = NTSC (3.58/60).
3 = NTSC (4.43/60).
4 = PAL (4.43/50).
5 = PAL (4.43/60).
6 = SECAM (50Hz).
7 = B & white (50Hz).
8 = B & white (60Hz). 9 = YUV 50 Hz.
10 = YUV 60 Hz.
11 = RGB 50 Hz.
12 = RGB 60 Hz.
13 = VGA1 350L.
14 = VGA2 400L.
15 = VGA3 480L.
16 = PLASMA 42".
17 = SVGA.
18 = MAC.
19 = XGA.
20 = PLASMA 50'.
21 = MAC 21'.
22 = SXGA.
23 = UXGA.
24 = 1080i @ 50 Hz.
25 = 1080i @59.94/60.
26 = 480p @ 59.94/60. 27 = 720p @ 59.94/60.
0 = RS232
1 = LAN
1 = reset.
1 = store.
0 = all IP address / ports
1 = IP local address / local port
2 = IP remote address / remote port
3 = IP gateway address.
local port: 10000 to 10999.
remote port: 0 to 65500.
Value = number of bit to 0 (from right).
example: 2
255.255.255.252
3
255.255.255.248
.............
8
255.255.255.0
.............
24
255.0.0.0
0 = UDP
1 = TCP
Rd = Read only command.
Rd/Wr = Read and write command.
OCTO range