Automatic repositioning
If the programmer blocks due to an encoder count error
programmer reset
, the warning lights and indicator light will flash simul-
taneously for 2 seconds and will then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after
pre-flashing for 10 seconds) automatically move the gate, slowly, to the
completely closed position (2 times as in the programming procedure) in
order to recover the correct position.
DISPLAY MODE
Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
The status of the security devices
CSP
are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "V41")
The segments regarding the command status
(LED "ON"
command active) and safety status
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the test mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices. The warning
lights
will
activate
"TA-TC-TAL-TD-TB- FTCI-CSP" command is
received. In this mode you can activate serial line
communication by using the external program,
which is to be connected to the CSER connection
via cable (fig. 3). While communication is active
dashes will appear on the display; after 5 seconds
of inactivity you will be moved back to the
mode. To return to the normal operating mode
press the "test" command again and wait for 10
seconds.
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
Each time PROG is pressed
the limited opening distance,
measured
in
metres,
increase (from 1 to 9).
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
TB
FTCI
,
and
settings
and
est) light up.
once,
each
time
a
PRESS
will
10 sec
PROG
At this point the programmer will function normally.
To carry out automatic repositioning without waiting for 3 minutes you may
or after a
send a (TA, TC, TAL or TD) command to the programmer.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
PROG
- display the number of manoeuvres;
test
- set the limited opening distance;
- setting the current sensor level
PRESS PROG
10 sec
PRESS PROG
10 sec
PRESS PROG
PRESS PROG
10 sec
PRESS PROG
PRESS PROG
Each time PROG is pressed
the number will increase (from 1
to 9).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 4)
19
.
When the
TA-TC-TD-TAL-TB-FTCI-CSP
inputs are activated the warning lights will light up.
5 sec
Connect the
programming device
PRESS PROG
(CSER) and activate it.
10 sec
Setting the current sensor.
que ( max. 9 amps )
10 sec
PRESS PROG
3 minutes,
10 sec