Télécharger Imprimer la page

Samoa 556 Série Guide D'instructions Et Pièces De Rechange page 6

Publicité

Les langues disponibles

Les langues disponibles

EN
OPERATING INSTRUCTIONS
THIS PUMP IS SELF-PRIMING.
To prime it the first time, you must connect the air pump supply to a low
pressure using the pressure regulators while keeping the outlet valve open.
When fluid begins to flow from the pump outlet, the pump is primed. For
regulation of fluid pressure, the unit must be supplied with an air pressure
STOPPING THE PUMP FOR MAINTENANCE TANKS
• Stop the air supply.
• Make sure for your safety that the air valve is closed.
• Turn off the air compressor, or close the valve on the air supply side of
the auxiliary equipment.
• Close the discharge valve and the suction valve. Open inlet and outlet
drain valves.
GROUNDING THE PUMP
• When installing the pump, be sure to perform grounding in the specified
location.
• Also connect ground wires for the auxiliary equipment and piping.
• Use a grounding cable of at least 12 gauge (2.0 mm
• If the pump you have purchased is valid for Atex, a specific Atex manual
will accompany this one. Read this manual before operating the pump.
WARNING
• Connect grounding wires to the pump, piping and all other equipment too.
• When the pump operates ungrounded or with an incorrect connection, friction between parts and abrasion caused by some fluids that flow inside the
pump, can generate static electricity. Moreover, according to the type of fluid pump and the installation environment (such as gases in the air or the
type of the surrounding facilities) static electricity can cause fire or electric shock.
6
855 835 R. 09/21
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
DISCHARGE
VALVE
OUTLET
DRAIN
VALVE
).
2
THE POSITION
OF THE
GROUND WIRE
between 14 and 100 psi (1 and 7 bar). Adjust the discharge valve on the
discharge side to control flow. For the performance characteristics of the
pump see the capacity curve shown on page 2.
• Open the air valve of the pump, running bring on the pump and flushing
the remaining fluid.
• Close the air valve.
• After ensuring that the pump was turned off and the pressure was released,
pump is ready for its maintenance.
AIR VALVE
SUCTION
VALVE
INLET
DRAIN
VALVE
• If the unit is marked with the symbol,
explosive atmospheres. Below this symbol, in the nameplate of the pump,
are indicated the areas for which the equipment is approved. You will also
find the maximum allowable surface temperature in the same plate.
it can be used in potentially

Publicité

loading

Ce manuel est également adapté pour:

Dc20 série