2. Connect the other end of the power cord for the
battery charger in an grounded mains socket. The
LED on the battery charger flashes green one time.
(Fig. 48 )
3. Put the battery in the battery charger. The green light
on the charger comes on when the battery is
correctly connected to the battery charger.(Fig. 49 )
4. When all LEDs on the battery have come on the
battery is fully charged. Charge the battery for
maximum 24 hours.
5. To disconnect the battery charger from the mains
socket, pull the plug, not the power cord.
6. Remove the battery from the battery charger.
Battery charging status
A Husqvarna Li-ion battery can be charged or used at all
charging levels. The battery is not damaged. A fully
charged battery will not decrease its charge when the
battery is left in the charger.
LED display
LED 1 flashes
LED 1 is lit, LED 2 flashes 25%-50%
LED 1, LED 2 are lit, LED
3 flashes
LED 1, LED 2, LED 3 are
lit, LED 4 flashes
LED 1, LED 2, LED 3,
LED 4 are lit
To operate LC 141VLi and LC 141Li
To start the product
1. Put a charged battery in the battery compartment.
2. Turn the safety key to 1.(Fig. 50 )
3. Stay behind the product.
4. Press the ON/OFF button (A) on the control panel
and the green LED (B) comes on.(Fig. 51 )
5. Loosen the start inhibitor.(Fig. 52 )
6. Push the motor brake handle in the direction of the
handlebar.(Fig. 53 )
To use the drive on the wheels
•
Model LC 141VLi. Pull the drive bail in the direction
of the handlebar to start the drive.(Fig. 54 )
•
Press + and - on the control panel to set the drive
speed in 4 steps.(Fig. 55 )
•
Release the drive bail to disengage the drive, for
example when you go near an obstacle.
To use the SavE function
The product has a battery saving function (SavE) that
gives longer operation time.
71 - 005 - 18.05.2018
Charging status
0%-25%
50%-75%
75%-100%
Fully charged
1. Press the SavE button (A) to start the function. The
green LED comes on.(Fig. 56 )
2. Press the SavE button again to stop the function.
The green LED (B) goes out.
The SavE function stops automatically if the ground
conditions make it necessary to have a higher output.
The SavE function starts automatically when the ground
conditions lets it.
High load function
When the product cuts long or wet grass, the motor
automatically increases rpm. The motor goes back to
standard mode when high load is not necessary.
To stop the product
The product stops automatically if you do not operate it
for 10 minutes. Always turn the safety key to 0 before
you let the product out of view.
1. Release the motor brake handle to stop the motor.
(Fig. 57 )
2. Press the ON/OFF button (A) on the control panel
and the green LED (B) goes out.(Fig. 58 )
3. Open the battery lid and turn the safety key to 0.(Fig.
59 )
4. To remove the battery, press the 2 release buttons
and pull out the battery.(Fig. 60 )
5. Charge the battery if it is weak. For more
To charge the battery on page 20 .
information, see
To operate LC 141C)
To select an approved cable (LC 141C)
Note: For the UK market, use only the 16M extension
cable that comes with the product. For all other markets,
refer to the information below.
If extension cables are used, these must comply with the
minimum cross-sections in the table below:
Voltage
Cable length
220-240V/ 50Hz
Up to 20 m
220-240V/ 50Hz
20–50 m
•
Mains cables and extension cables are available
from your local approved service agent for
Husqvarna outdoor products.
•
Only use extension cables specifically designed for
outdoor use and which conform to one of the
following specifications: Ordinary rubber (60245 IEC
53), Ordinary PVC (60227 IEC 53) or Ordinary PCP
(60245 IEC 57)
•
If the cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Cross section
2
1.5 mm
2
2.5 mm
21