20. Fault Correction
Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
21. Replacement Parts
Designation
1 Aerator with flow-
regulator (VPE 10 St.) . . . . . . . . . 81-013-03.057
2 Lithium battery 6 V type CRP2 . . . 85-032-02.830
3 Solenoid valve cartridge
with grit filter . . . . . . . . . . . . . . . . 85-100-20.578
4 Cleaning clip . . . . . . . . . . . . . . . . 85-032-02.831
5 Maintenance kit comprising:
Non-return valve
Grit filters. . . . . . . . . . . . . . . . . 81-500-03.028
6 Hose . . . . . . . . . . . . . . . . . . . . . . 82-024-03.123
10
Cause
– Battery dead (red LED lights up)
– Water-flow volume regulator closed
– Grit filters are clogged with dirt
– Cleaning clip in front of the fitting
– Electronic system in sleep mode
– Solenoid valve faulty
– Solenoid valve faulty
– Corner valves not fully opened
– Grit filters are clogged with dirt
– Aerator calcified
– Supply pressure too low
– Cold water is turned off
– Filter in cold-water part is dirty
– Non-return valve faulty
– Hot water is turned off
– Filter in hot-water part is dirty
– Non-return valve faulty
Order No.
info@hygiene-shop.eu - www.hygiene-shop.eu
Designation
7 Maintenance kit comprising:
O-rings
Screws
Grit filters . . . . . . . . . . . . . . . . . 85-500-03.012
8 Mixing lever with screw . . . . . . . . . 85-100-20.198
Accessories
9 Remote control . . . . . . . . . . . . . . . 5207 10 00
10 Base for installation on
stainless steel washbasin . . . . 85-500-02.021
Remedy
➯ Replace it
➯ Open it
➯ Clean them
➯ Remove
➯ Shine bright light
in front of the
sensor
➯ Replace it
➯ Replace it
➯ Open it
➯ Clean them
➯ Clean them
➯ Check it
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Replace it
➯ Replace it
Order No.
Order No.