8.
Dimensions
9.
Installation Example
10. Assembly Instructions
Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and
cause a health risk or even risk of death.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
☞
Do not shorten the connector hoses located at the fitting.
☞
Only use a 6 V lithium battery type CRP2 as a power supply.
10.1 Install the fitting (a) on the washbasin (b).
☞
Important!
Observe the range settings when installing on a stainless steel washbasin
Chapter
13.
☞
The corner valves (c) must be provided by the customer.
10.2 Screw the connecting hose (d) on to the corner valve.
11. Function
11.1 Allow your hand to approach the sensor.
• Water flows.
11.2 Remove your hand from the sensor.
• Water flow stops automatically after a set flow duration.
☞
The range of the sensor and the flow duration can be adjusted with the optional
remote control (FAR Order No. 5207 10 00).
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections (see
6
Chapter 13.
for adjusting the sensor range).