14. Adjustments
Various adjustments can be made using the free software
(FAR-Order-No. 4897 00 00).
☞
The shower remains locked for 2 min after each shower procedure. This time of
occupancy can not be changed.
Adjustable Parameters
• Payment time:
– Time during which the coins or tokens must be inserted into the counter. The
shower is enabled after this time has elapsed.
Additional coins are not counted.
– Adjustable range: 1-30 sec
– Factory setting: 10 sec
• Delivery unit:
– Duration of media deliver per paid unit. Up to 30 coins can be inserted.
– Adjustable range: 1-510 sec
– Factory setting: 3 min
• Expiration time:
– Time until the credit expires when not used. The shower is enabled for
payment.
– Adjustable range: 1-30 min
– Factory setting: 5 min
15. Maintenance and Servicing
• The coin-activated switch does not require special maintenance.
• Use a moist microfibre cloth to remove any external soiling on the housing.
16. Fault Correction
Fault
Water does not flow
Water flows conti-
nuously
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Voltage supply interrupted
– Coin-activated switch faulty
– Coin-activated switch faulty
- 9 -
Remedy
➯ Restore it
➯ Replace it
➯ Replace it