The BOTTICELLI B CRC 480 D01 system is suitable for motorising sectional doors
(fig. C), protruding fully retracting spring-operated overhead doors (fig. B) and
counterweight overhead doors provided with an appropriate towing arm (fig. D).
The overhead door must not be higher than 3 metres. Its easy installation allows
fast fitting without needing the door to be modified. The irreversible gearmotor
keeps the door locked in the closing position.
2) TECHNICAL SPECIFICATIONS
ATTUATORE
Power supply
Motor voltage
Max. power absorbed from mains 180W
Lubrication
Towing and pushing force
Working stroke
Average speed
Impact reaction
Manoeuvres in 24 hours
Limit switch
Courtesy light
Working temperature
Degree of protection
Motor head weight
Noise level
Dimensions
CONTROL PANEL
Supply to accessories
Torque limiter setting
Blinker connection
Service light switching-on time
Incorporated rolling-code radio
receiver
Coding
No. combinations
Antenna impedance
Max no. radio controls to be
memorised
Fuses
(*) Available in all mains voltages.
(**)By turning the motor head by 90° (Fig.N) the useful stroke will be 2580 mm.
(***)By turning the motor head by 90° (Fig.N) the useful stroke will be 3180 mm.
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
3) ELECTRICAL INSTALLATION SET-UP Fig.A
Arrange for the connections of accessories and safety and control devices to
reach the motor unit, keeping the mains voltage connections clearly separate
from the extra low safety voltage connections (24V).
Proceed to connection following the indications given in the wiring diagram.
The cables for connecting the accessories must be protected by a raceway (fig.
K ref. 5C1).
4) ACTUATOR INSTALLATION
4.1) Preliminary checks
• Check that the door is balanced.
• Check that the door slides smoothly along its entire travel.
• If the door has not been newly installed, check the wear condition of all its
components.
• Repair or replace faulty or worn parts.
• The automation reliability and safety are directly influenced by the state of
the door structure.
• Before fitting the motor, remove any superfluous ropes or chains and disable
any unnecessary appliances.
4.2) FITTING
1) Remove the existing locking bolt from the cremone bolt of the door.
2) Fit the metal wall bracket to the track-holder bracket using the screws sup-
plied as standard (Fig.E1). The screws must not be tightened, so that the
bracket can be rotated.
3) In order for the track to be correctly fixed, mark the mid-point of the door,
position the BIN onto the ceiling and mark the holes (Fig.F).
Make sure that the distance between the track and the door panel is com-
prised between 108 and 166 mm (see Fig.G).
various combinations for fastening the bracket to the overhead door.
14 -
BOTTICELLI B CRC 480 D01
INSTALLATION MANUAL
230V ~±10%, 50/60Hz single-phase (*)
24V
permanent grease
800 N
BINARIO L.=2900 working stroke=2400 mm (**)
BINARIO L.=3500 working stroke=3000 mm (***)
5 m/min
integrated torque limiter on control panel
20
Electronic with ENCODER
~
24V
25W max, E14 bulb
-15°C / +60°C
IPX0
5 kg
<70dB(A)
see fig.1
24V~ (180mA max)
24Vsafe (180mA max)
on closing and opening
24V~ max 25W
90s
Frequency 433.92 MHz
rolling-code algorithm
4 milliard
50 Ohm (RG58)
63
see figure T
The table in Fig. H gives the
4) Drill the ceiling using a D.10 bit, with reference to the markings made previ-
ously, and insert the plugs. Fig. I.
5) Secure the track at the base, fig.J (1-2), K (3-4-5).
6) With the help of an adequate support, lift the entire motor, screw the screws
onto the track-holding bracket without fixing them to the door frame (Fig.
L1) or, if the height allows it, fit the bracket to the masonry lintel by means
of plugs (Fig.L2).
7) Rest the motor onto the floor (taking care not to damage it) and fix the
articulated bracket to the door frame or to the ceiling.
8) In the case where the motor is not directly fixed to the ceiling, fit the brack-
ets as shown in Fig.M, after marking and drilling the holes with reference to
the brackets.
9) In the case where the track is turned by 90° with respect to the motor head,
use the reference template in Fig. N1 to cut out the guard, keeping to the
measurements indicated. For track fitting to the ceiling, see Fig.F (for tracks
fitted lower, see Fig.E).
10) In the case where the track is made in two halves, see Fig.O; for the different
types of fixing methods, see the previous figures.
11) Release the carriage and fix the anchoring brackets to the door panel (Fig.H).
The distance allowed between track and sectional door is 108 to 166 mm.
In case of greater distance, it is necessary to use the brackets and lower the
motor; in case of shorter distance, it is necessary to shorten the towing plate.
12) Stick the adhesive labels supplied next to the dangerous points (Fig. Q).
5) CHAIN TIGHTENER ADJUSTMENT (BOTTICELLI B CRC 480 D01)
The operator supplied is already calibrated and inspected. Should the chain ten-
sion need to be adjusted, proceed as shown in fig. R.
WARNING: the anti-tear rubber element must never be completely com-
pressed. Scrupulously check that the rubber does not become totally com-
pressed during operation.
6) MANUAL RELEASE (See USER GUIDE -FIG.1-).
6.1) REMPLACEMENT DE L'AMPOULE (FIG.2)
----------------------------------------------------------
7) TERMINAL BOARD CONNECTIONS (FIG.T)
TERMINAL
DESCRIPTION
JP2
transformer wiring
JP10
motor wiring
Antenna input for integrated radio-receiver board
1-2
(1: BRAID. 2: SIGNAL)
3-4
START input (N.O.)
3-5
STOP input (N.C.) If not used, leave the jumper inserted.
3-6
PHOTOCELL input (N.C.) If not used, leave the jumper inserted.
FAULT input (N.O.)
3-7
Input for photocells provided with checking N.O. contact
8-9
24 V~ output for blinking light (25 W max)
24V~ 180mA max output – power supply for photocells or
10-11
other devices.
24V~ Vsafe 180mA max output – power supply for checking
12-13
photocell transmitters.
14-15
PARTIAL OPENING input
16-17
Ingresso APERTURA PARZIALE (N.O.)
8) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
8.1) TESTED DEVICES Fig. T1
8.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS Fig. T2
9) CALLING UP MENUS: FIG. 1
9.1) PARAMETERS MENU (PARA ) (PARAMETERS TABLE "A")
9.2) LOGIC MENU (LOGIC) (LOGIC TABLE "B")
9.3) RADIO MENU (radio) (RADIO TABLE "C")
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
• Cloning of master transmitter (rolling code or fixed code).
• Cloning to replace transmitters already entered in receiver.
• Transmitter database management.
• Receiver community management.
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
9.4) MENU DEFAULT (default)
Restores the controller's DEFAULT factory settings. Following this reset, you will
need to run the AUTOSET function again.

Publicité

Table des Matières
loading

Table des Matières