conveRsIon fRom flow below The seaT
To flow above The seaT
Danger!
Danger – high pressure!
• Turn off the pressure and vent the lines before loosening lines or
valves.
Risk of injury from improper maintenance!
• Maintenance may be performed by authorized technicians only!
• To screw on or unscrew valve body or actuator, use an open-end
wrench, never a pipe wrench, and observe tightening torques.
Required parts:
Item
28, 29
2 Pressure springs for actuator C (40 mm),
D (50 mm), E (63 mm), F (80 mm)
Procedure:
1
Mount valve
on the body.
InsTallaTIon Tools
Installation wrench for actuator C (40 mm) and D (50 mm)
Actuator
ø (mm)
C
D
Installation wrench for actuator E (63 mm)
Actuator
ø (mm)
E
Description
Order no.
40
639 175
50
639 175
Order no.
63
639 170
Caution!
Danger through taut springs!
• Carefully open piston actuator!
31
Release cover
with special wrench until the springs are
completely relaxed, holding up the actuator body
hexagon.
For information about the special wrench, see Chapter
"Installation tools".
Remove and / or insert pressure springs
actuator.
For actuator size C (40 mm), D (50 mm), E (63 mm) and
F (80 mm): Remove pressure springs and insert new, weaker
springs.
For actuator size G (100 mm) and H (125 mm): Remove outer
29
28
spring only
, inner spring
31
Mount cover
and screw tightly with special wrench.
Check the valve for function and leaks.
Note changed direction of flow and changed pressure range!
Installation wrench for actuator F (80 mm), G (100 mm) and
H (125 mm)
Actuator
ø (mm)
F
80
G
100
H
125
12
against the
28 29
depending on
remains in the actuator.
Order no.
639 171
639 172
639 173