ALARM SIGNALS
Any repairs must be carried out exclusively by the authorized service centre or by qualified personnel.
Warning: unplug the appliance before performing any operations.
ALARM
DESCRIPTION
ALAr
• Pellets hopper
Hot PEL
temperature higher than
permitted.
• The fuel was not lit during
ALAr
no Acc
startup and fire has not
been detected.
ALAr
• Smoke evacuation stack
clogged.
no ASP
ALAr
• Pellets hopper or
Sic
tangential fan temperature
FAiL
higher than permitted.
ALAr
• Smoke evacuation stack
deP FAiL
clogged.
• Smoke evacuation motor
ALAr
Fan FAiL
not running.
ALAr
• Fire no longer detected on
no FirE
burner grate.
ALAr
• The smoke temperature
Hot tEMP
exceeded alarm value.
ALAr
• Smoke probe broken.
Sond
Fumi
CooL
• Appliance cooling.
FirE
• Room temperature not
ON 1...5
detected.
on t
ALAr
If the glow plug breaks, while waiting for it to be repaired the start button can be pressed and the
no Acc
pellets lit manually using a cube of fire lighter material.
F
CAUSE
• Upper or front air vents obstructed.
• Detection probe broken.
• Convection motor broken.
• Pellets not being fed.
• Glow plug broken.
• Fire not detected by smoke probe.
• Pellets cannot be lit.
• Stack clogged.
• Electrical connections interrupted.
• Pressure switch broken.
• Room in vacuum.
• Upper or front air vents obstructed.
• Temperature thermostat broken.
• Convection motor broken.
• Stack clogged.
• Electrical connections interrupted.
• Pressure switch broken.
• Room in vacuum.
• Electrical connections.
• Motor broken.
• No rotation.
• Pellets not being fed.
• Convection air outlet obstructed.
• Convection motor broken.
• Smoke probe position error.
• Excessive flame in furnace.
• Electrical connections interrupted.
• Probe broken.
• Voltage drop.
• Room temperature probe broken.
GB
REMEDY
• Check upper and front air vents.
• Replace probe.
• Check convection motor.
• Check for pellets in hopper and for
sawdust on bottom of hopper.
• Check auger.
• Check electrical connections.
• Replace glow plug.
• Check
connection of smoke probe.
• Improve fuel quality.
• Check stack.
• Check electrical connections.
• Replace pressure switch.
• Check fresh air intake.
• Check upper and front air vents.
• Replace thermostat.
• Check convection motor.
• Check stack.
• Check electrical connections.
• Replace pressure switch.
• Check fresh air intake.
• Check
connections.
• Check
connections.
• Replace motor.
• Check for mechanical blockage, try to
turn the motor manually.
• Check for pellets in hopper and for
sawdust on bottom of hopper (see
Cleaning the pellets hopper sect. 3.1).
• Check auger.
• Check upper and front air vents.
• Check convection motor.
• Check
connection of smoke probe.
• Clean the grate, leave to cool and
switch back on. If this problem
persists, the service centre or a
qualified
contacted.
• Check probe is correctly connected.
• Replace smoke probe.
• Wait for automatic restart.
• Check room temperature probe.
• Replace room temperature probe.