CoolAir RT780
8
Configuration of unit software
Before you first start up the unit, the controls can be adapted to suit the
installation conditions. This must be done by the person installing the unit.
In configuration mode, the following unit software parameters must be set
at the control panel (fig. 7, page 6).
Menu
Parameter
level
1
Set temperature
2
Low voltage
cut-off
3
Operating mode
4
Default settings
5
Temperature unit
display
I
NOTE
Configuration mode can still be activated if the undervoltage protection
mechanism has switched off the unit and only residual voltage is
available.
EN
Configuration of unit software
Meaning
The unit starts at the temperature
defined here.
The battery monitor shuts down the unit
at the voltage defined here.
The unit starts with the operating mode
defined here.
Parameters 1 – 3 can be reset to the
default settings.
The temperature can be displayed in °C
or °F.
Default
setting
20 °C (68 °F)
Characteristic
figure 4 =
22,8 V
0 = Automatic
mode
--
°C