Télécharger Imprimer la page

LK Armatur ThermoMat G Manuel D'instruction page 2

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
GB
ENGLISH
General Information
LK 810 ThermoMat G is an automatic loading unit for solid-
fuel boiler/storage tank installations. The loading unit ensu-
res a minimum return-water temperature into the heating boiler,
which increases boiler effi ciency, prevents tarring and considera-
bly prolongs the lifetime of the heating boiler.
LK 810 ThermoMat G eliminates the risk of destructive thermal
shock caused by surges of cold return water and renders a more
effective burning. The heating boiler quickly reaches the right
working temperature. In the end phase of the fi ring an automatic
balancing valve closes the by-pass loop. This results a maximum
Technical Data
Voltage
Power consumption
Max. boiler effi ciency
Return temperature
Working temperature
Ambient temp.
Max. working pressure 1.0 MPa (10 bar)
Max. fl ow
Media
Thread standard
Circulating pumps
Material, valve body
Material, insulation
Pump Characteristics
70
60
III
II
50
40
I
30
20
10
0
0.0
0.5
1.0
Left-hand mounting
Left-hand mounting
Storage Tank
Storage Tank
230 VAC 50 Hz
65-95 W depending on pump speed
65 kW at 20°C ΔT
55°C, 60°C, 65°C or 70°C
Min. +5°C/Max. +110°C
Min. +5°C/Max. +60°C
2800 l/h
Water - Glycol mixture max. 50%
Rp - female thread
Grundfos UPSO 65 Low Energy
Brass EN 1982 CB753S
Expanded Polypropylene EPP
1.5
2.0
2.5
Flow (m³/h)
Heating Boiler
Heating Boiler
cooling of the boiler and the storage tank is fully fi lled with hot
water.
LK 810 ThermoMat G automatically allows self-circulation as soon
as the fi re has gone out so that the rest of the heat in the boiler is
transferred into the storage tank. It also allows self-circulation in
case of power failure.
LK 810 ThermoMat G loading unit is normally service free. The
valve unit has three ball valves. Any part can be changed without
draining the system.
Main Parts
1. Thermally operated loading valve
2. Automatic balancing valve
3. Backfl ow preventer, depending on model
4. Circulation pump, Grundfos UPSO 65 Low Energy
5. Three thermometers
6. Three ball valves
7. Insulation EPP
100
80
60
40
20
0
3.0
0.0
Heating Boiler
Heating Boiler
Boiler Capacity Diagram
0.5
1.0
1.5
Flow (m³/h)
Right-hand mounting
Right-hand mounting
2.0
2.5
3.0
Storage Tank
Storage Tank

Publicité

loading

Ce manuel est également adapté pour:

Lk 810