emmeti XECO Série Manuel D'installation page 52

Masquer les pouces Voir aussi pour XECO Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6. EXTERNAL UNIT INSTALLATION
Aluminised tape
Refrigeration piping
Indoor unit condensation drain
Electrical connection cable
between the units
- Provide to use a protection sheet for the cables exposed to the outside.
- It is recommended to set the cables with a drip-proof run in order to
avoid possible infiltrations of water in the outdoor unit.
- Combine the electrical connection cable of the two units to the refrigera-
tion piping and wrap with reinforced tape, possibly alluminized (Fig. C).
- If the cable cannot be solid with the piping, make a suitable wall ancho-
rage by means of a cable fastener or hose clips..
6.4.4
Connection to the outdoor unit terminal board
- Remove the two fixing screws and take off the terminal board cover as
shown in fig. D, E, F.
- Connect the cable to the terminal block as shown Fig. G
Single Hi-Wall
Fig. D
Dual Hi-Wall
Fig. E
52
Trial Hi-Wall
Fig. C
Fig. F
- Loosen the screws and insert the ends of the cable completely into the
terminal block, after this tighten the screws.
Fig. G
- Pull the cable lightly to make sure that the cables have been insert and
fixed rightly.
- After cables connection never forget to tight them to the cable gland.
GB
GB
70 mm
10 mm
10 mm
50 mm
Un
All'u

Publicité

Table des Matières
loading

Table des Matières