Commissioning
With hand terminal
The user menu − The 10 most important drive parameters at a glance
After every mains connection with connected hand terminal or connecting the hand terminal during
operation to the AIF interface, the 10 codes specified in the user menu (Code C0517) are immediately
available.
The user menu is set to all codes at the factory to allow for commissioning a standard application:
Code
Designation
C0054 Apparent motor current of
motor 1
C0055 Apparent motor current of
motor 2
C0006 Transfer HW/hand terminal
C0120 Rated current
1 Motor 1
2 Motor 2
C0410 Configuration of digital input
signals
1 Motor 1 start/stop
2 Motor 2 start/stop
3 Brake control
4 ... 24
C0415 Configuration of digital
output signals
1 X3/A1
2 X3/A2
3 X3/A3
4 X3/A4
5 ... 6 AS−I output bit
C0012 Motor voltage acceleration
time
1 Motor 1
2 Motor 2
C0423 Delay time of "Release
brake"
C0424 Delay time of "Apply brake"
C0002 Parameter set management
106
Lenze setting
Display only
Display only
0
Setting the acceleration time (C0012) and starting voltage
(C0016) via potentiometer, setting the rated motor current
(C0120) via stepping switch
Rated motor current for I
Accepts the value from the stepping switch:
If C0006 = 0, 2, 4, 6:
l
– Display only
If C0006 = 1, 3, 5, 7:
l
– Rated current can be set via C0120
1
X3/E1
2
X3/E2
3
X3/E3
255
Not assigned
3
Status of motor 1
4
Status of motor 2
5
Status of brake
25
TRIP error message
255
Not assigned
Time for voltage change U
Accepts the value from potentiometer "T"
If C0006 = 0, 1, 2, 3:
l
– Display only
If C0006 = 4, 5, 6, 7:
l
– Acceleration time can be set via C0012
0.00 s
0.00 s
See code table
EDK71MMXXX−020 DE/EN/FR 5.0
2
t monitoring
... U
0
mains
L