6.3 Master tool calibration.
Once the home references are found on the linear encoders (scales), access the menu using the
"Master" option. The screen will display the message: "Calibrate with master".
Depending on the value of PAR 64, the data protection option will request a password or not. This password is: 719200
Once in the "calibration with master" mode, place the master tool in the machine and move it to the desired position. At
this point, preset the coordinates of the master for each axis so the reading is referred to the master.
The next time the machine is turned on, it will suffice to find the reference marks on the linear encoder and the DRO will
automatically refer its position reading to the master. Therefore, if the reference marks are found (axes homed), it is no
longer necessary to adjust the master every time the machine is turned on.
Tool calibration.
Once the master tool has been calibrated, another tool may be calibrated. To do this, just press the
calibration.
The screen will display the tool number with a text
Calibrate
Begin at ...
Key in the desired tool number and press ENTER.
It will then ask for the reference to use.
Reference
Number:
Once this data has been entered, press ENTER and actuate the footswitch, the tool will be calibrated and the dro will
request the next tool.
The type of tool being calibrated may be changed at any time by pressing the
Likewise, the reference associated with the tool can also be changed by pressing
If Bit 4 of PAR64 is active, the DRO will request a reference number every time a tool is calibrated.
To quit tool calibration, press CLEAR or
- FAGOR AUTOMATION S. COOP -
- Page 4 of 5 -
key and select the
key for tool
key.
[ Reference Nr ] and ENTER.