1 Operating Elements and Connections
(fig. 3)
1 DMX input (3-pole XLR)
2 DMX output (3-pole XLR)
3 Fuse; replace a burnt-out fuse by one of the same
type only
4 Cold appliance chassis plug for mains connection
(230 V~/50 Hz)
5 Trimming potentiometer for adjusting the micro-
phone sensitivity
6 DIP switches for adjustments in the master/slave
mode and for adjusting the DMX start address und
reversing the sense of mirror rotation
(for details see chapter 6).
7 LED to indicate operation
8 Mounting bracket
9 Setscrews
2 Safety Notes
This unit corresponds to the directive for electromag-
netic compatibility 89/336/EEC and to the low voltage
directive 73/23/EEC.
Please observe the following items in any case:
The unit is suitable for indoor use only. Protect it
against dripping water and splash water, high air
humidity, and heat (admissible ambient temperature
range 0 – 40 °C).
The unit heats up very much during operation. To
prevent burning yourself, never touch the housing
during operation; let the unit cool down for a few
minutes after switching off before you touch it.
The heat generated within the unit must be carried
off by air circulation. Therefore, do not cover the air
vents of the housing.
Do not insert anything into the air vents. This may
result in an electric shock!
Do not operate the unit or immediately disconnect
the plug from the mains socket
1. if there is visible damage to the unit or to the
mains cable,
2. if a defect might have occurred after the unit was
dropped or suffered a similar accident,
3. if malfunctions occur.
Attention!
The unit is supplied with hazardous mains voltage
(230 V~). Inexpert handling may cause an electric
shock hazard. In any case the unit must be re-
paired by skilled personnel.
Never pull the mains cable for disconnecting the
mains plug from the socket.
For cleaning only use a dry, soft cloth; never use
chemicals or water.
No liability for any damage will be accepted if the
unit is used for other purposes than originally intend-
ed, if it is not correctly installed or operated or not
repaired in an expert way.
If the unit is to be put out of operation definitively,
take it to a local recycling plant for a disposal which
is not harmful to the environment.
Important for U. K. Customers!
The wires in this mains lead are coloured in accor-
dance with the following code:
green/yellow = earth
blue = neutral
brown = live
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug, pro-
ceed as follows:
1. The wire which is coloured green and yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol
or coloured green or green and yellow.
2. The wire which is coloured blue must be con-
nected to the terminal which is marked with the
letter N or coloured black.
3. The wire which is coloured brown must be con-
nected to the terminal which is marked with the
letter L or coloured red.
Warning - This appliance must be earthed.
3 Applications
The light effect units LE-500DMX ("Scanner") and
LE-510DMX ("Roller Scanner") are ideally suited for
stage and disco applications. The units project various
multicoloured geometric patterns providing an ideal
dance floor atmosphere. Light control is made via an
integrated microphone or in combination with a light
control unit via the DMX512 connection.
3.1 Accessories
The following units are available from "img Stage Line"
for controlling the scanners:
Miniature DMX controller LE-500C
(order No. 38.1520)
for controlling the scanner LE-500DMX
Miniature DMX controller LE-510C
(order No. 38.1530)
for controlling the roller scanner LE-510DMX
4 Inserting a Lamp
The light effect unit is supplied without lamp. A halogen
lamp 15 V/150 W with a GZ 6.35 lamp base (e. g.
HLO-15/150MR available from "img Stage Line") is
required.
Never use lamps with a wattage higher than 150 W!