For the cleaning of the majolica we suggest you to use a soft and dry cloth; if you use a detergent or liquid, the latter
might soak in and make the crackles more visible.
14. SUMMER STOP
After cleaning the hearth, chimney and hood, totally eliminating the ash and other eventual residues, close all the
doors of the hearth and the related registers and disconnect the equipment from the chimney.
We suggest to perform the cleaning operation of the flue at least once per year; verify in the meantime the actual
status of the gaskets which cannot ensure the good operation of the equipment if they are not perfectly solid! In this
case the gaskets must be replaced.
In presence of dampness in the room where the stove has been placed, we advise you to put absorbent salts into the
hearth.
If you want to keep for long the aesthetic look of the cooker it is important to protect its parts in row cast iron with
neutral Vaseline.
15. CONNECTING A CHIMNEY OR OPEN FURNACE TO THE FLUE
The smoke channel is the section of tube that connects the product to the flue, in the connection these simple but
very important principles must be followed:
•
for no reason must the smoke channel be used with a diameter lower than that of the neck of the outlet with
which the product is fitted;
•
each metre of horizontal route of the smoke channel causes a small leak of charge which should be
compensated for by raising the flue;
•
the horizontal section must never be higher than 2 m
(UNI 10683-2005);
•
each bend of the smoke channel considerably
reduces the draught of the flue which must be
compensated for by raising it suitably;
•
the UNI 10683-2005 Regulation –Italy requires that
the bends or variations of direction must in no case
be greater than 2 including the emission into the flue.
Wanting to use the flue of a chimney or open furnace, it will
be necessary to close the hood hermetically below the inlet
point of the smoke channel pos. A Picture 10.
If the flue is too large (e.g. cm 30x40 or 40x50) it is necessary
to duct it with a stainless steel tube of at least 200 mm of
diameter, pos. B taking care to close the space between the
tube itself and the flue immediately below the chimney cap
pos. C.