CLASSICA 350 – 450
d) no flammable components (e.g. wall units) must be present above the cooker.
The cooker must operate exclusively with the ash drawer inserted. The solid residues of the combustion (ashes) must
be collected in an hermetic container, resistant to fire. The cooker must never be ignited near when there are gas or
steam emissions (e.g. glue for linoleum, gasoline, etc.). Never deposit flammable materials near the stove.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace glass, the
handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of these parts without
gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney fire.
4.1. FIRST-AID MEASURES
Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door.
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable points.
5. FLUE
Essential requirements for a correct operation of the device:
• the internal section must be preferably circular;
• be thermally insulated and water-proof and produced with materials suitable to resist to heat,
combustion products and possible condensates;
• not be throttled and show a vertical arrangement with deviations not greater than 45° ;
• if already used, it must be clean;
1590001
– EN
A
B
30
dust).
2
30
Picture 2
17