Table of Contents
Introduction .............................................................................................................1
Cautions and Warnings (Intended Use) ............................................................1
Items Included .........................................................................................................2
Unpack ......................................................................................................................3
a) Attaching the Legs ..........................................................................................3
b) VitalSim Connections ....................................................................................3
Getting Started .......................................................................................................3
a) Cricothyroid Membrane ...............................................................................3
b) Pupil Replacement .........................................................................................3
In Use ........................................................................................................................3
a) Obstructed Airway ........................................................................................3
b) Tension Pneumothorax Decompression...................................................3
c) IV Cannulation ................................................................................................4
d) Intramuscular Injections ...............................................................................4
e) Urinary Catheterization ...............................................................................4
VitalSim Functionalities .........................................................................................4
a) Cardiac Related Skills ....................................................................................4
b) Blood Pressure Arm ......................................................................................5
c) Heart, Breath and Bowel Sounds and Speech .........................................5
After Use ..................................................................................................................5
a) Cricothyroid Membrane/ Neck Skin Collars ...........................................5
b) IV Cannulation ................................................................................................5
c) Intramuscular Injection .................................................................................5
d) Urinary Catheterization ...............................................................................5
e) Pneumothorax ................................................................................................6
i) Mid-Clavicular .............................................................................................6
ii) Mid-Axillary ................................................................................................6
f) Chest Drain ......................................................................................................6
Maintenance .............................................................................................................6
a) Cleaning ............................................................................................................6
b) Extend Cleanliness ........................................................................................6
c) Attaching/ Removing Arms ...........................................................................7
d) IV Arm Skin and Vein Replacement ............................................................7
TroubleShooting ......................................................................................................8
Technical Data .........................................................................................................8
a) General .............................................................................................................8
b) Wireless Remote Control ...........................................................................8
c) MegaCode Kelly Manikin ..............................................................................8
Parts ...........................................................................................................................8

Introduction

MegaCode Kelly is a full-body, lifelike manikin designed for the practice of
advanced, difficult and obstructed airway scenarios and IV therapy. When
used with the VitalSim Vital Signs Simulator; MegaCode Kelly allows cardiac
defibrillation, pacing with or without capture and variable threshold, ECG
interpretation of over 1100 rhythm variations, measurement of non-invasive
blood pressure, and the auscultation and recognition of heart, breath and
abdominal sounds. VitalSim also allows the use of the pre-recorded vocal
sounds, and live voice through the use of a wireless microphone and logging
and scenario functions.
The manufacturing quality of this manikin should provide many sessions of
training when reasonable care and maintenance are practiced.
Laerdal Recommends
Endotracheal Tube - Size 7.5
Laryngeal Mask Airway - # 4
Combitube- Large Adult or Trainer
KING LT - # 4
Needle or Catheter - Size 21-gauge or smaller
Cautions and Warnings - Latex
MegaCode Kelly
Cautions and Warnings
• This product contains Natural Rubber latex which may cause allergic
reactions when in contact with humans.
• There are electronic components mounted inside the airway head.The
following techniques should not be performed on this manikin due to the
inability to properly sanitize the airway if they are performed:
• Mouth-to-mouth/Mouth-to-mask ventilation
• Insertion of simulated vomit for suctioning
• Lubricate the oral and nasal airways liberally with the lubricant provided
prior to inserting any instrument, tube or airway device into the airway.
Additionally, instruments and tubes should also be lubricated prior to use.
• Do not allow the manikin's skin to come in direct contact with ink or
photocopied paper, as this can permanently stain the skin. Avoid using
colored plastic gloves when handling the manikin, as they may also cause
discoloration.
• Care should be taken when palpating the pulses to not use excessive
force as this will result in no pulse being felt. Only two individual pulses
can be felt at the same time.
• If a training session involves the administration of fluids and/or drugs into
the IV arm, empty the arm immediately following the training session.
• Defibrillation
• Only apply the defibrillator to a defibrillation post or zap plate which is
properly mounted on the manikin's chest.
• Do not provide more than 2 x 360J defibrillator discharges per minute as
an average over a period of time to prevent overheating.
• The manikin chest must be kept dry. Special attention should be taken
when using IV Arm.
• Do not apply conductive gel or conductive defibrillation pads intended
for patient use to prevent chest skin pitting.
• Do not use cables or connectors with visible damage.
• Observe all normal safety precautions for use of defibrillators.
• Defibrillation must be performed over the two defibrillation
connectors only.
This device generates, uses and possibly radiates radio-frequency energy. If
it is not installed and used in accordance with the instructions, it may cause
harmful interference to radio communications. In that case, the user is
encouraged to attempt correction of the interference by:
• Reorienting or relocating the receiving antenna.
• Increasing the distance between the device and receiver.
• Connecting the device to an outlet on a circuit different from that to
which the receiver is connected.
• Consulting the dealer or an experienced radio/TV technician for help.
Electromagnetic radiation from other radio transmitters or other
electronic equipment may cause noise in the head speaker. To eliminate
this noise, move manikin away from the radiation source or turn the head
speaker volume to zero.