ENGLISH
1. Introduction
We are pleased with your decision to purchase a
Twister evolution pro vacuum mixer.
Please read the following operating instruc-
tions carefully and observe the information
they contain in order to ensure a long and
trouble-free service life.

2. Application Area

The Twister evolution pro vacuum mixer is designed
solely for homogeneous, bubble-free mixing of dental
casting and modelling materials such as plasters,
investments as well as silicones.

2.1 Ambient Conditions

(in accordance with DIN EN 61010)
The unit may only be operated:
Indoors;
Up to an altitude of 2,000 m above sea level;
At an ambient temperature range between
5 - 40ºC [41 - 104ºF] *);
At a maximum relative humidity of 80% at 31°C
[87.8°F], dropping in a linear manner to 50% rela-
tive humidity at 40°C [104°F] *);
With mains power where the voltage fl uctuations
do not exceed 10% of the nominal value;
Under over-voltage category II conditions;
Under contamination level 2 conditions.
*) Between 5 – 30°C [41 – 86°F], the unit can be operated at
a relative humidity of up to 80%. At temperatures between
31 – 40°C [87.8 – 104°F], the humidity must decrease
proportionally in order to ensure operational readiness (e.g., at
35°C [95°F] = 65% humidity; at 40°C [104°F] = 50% humidity).
The unit may not be operated at temperatures above 40°C
[104°F].

3. Safety Information

3.1 Symbology
The following symbols are employed in these instruc-
tions and on the unit itself:
Danger
This indicates a direct risk of injury.
Electrical current
This indicates a hazard due to electrical
current.
Twister evolution pro
No. 1825-0000 / 1825-1000
Attention
Failure to observe the associated informa-
tion can result in damage to the unit.
Note
This provides the operator with useful
information to make working with the unit
easier.
Only intended for indoor use.
Before opening the unit, disconnect it
from the mains power supply by unplug-
ging the power cord from the wall outlet.
Observe the operating instructions.

3.2 Hazard Information

• The Twister evolution pro is an electric device
and, as such, carries with it a certain inherent
potential hazard.
• The unit may not be taken into service until any
required alterations to comply with regionally
specifi c power plug confi gurations have been
made. Such alterations may only be performed
by a qualifi ed electrician.
• The unit may only be operated if the
information on the nameplate conforms with
the specifi cations of your local mains power
supply.
• The unit may only be connected to a power
outlet with proper grounding.
• Only intended for indoor use. The unit is only
designed for dry applications and may not
be operated or stored outdoors or under wet
conditions.
• A damaged power cord must be immediately
replaced.
• Repairs to the open unit may only be performed
by specifi ed specialist personnel.
• Disconnect the unit from the mains power
supply before beginning any maintenance
tasks.
• Manipulating the automatic bowl coupler and
the intake opening can result in damage to the
unit and personal injury.
• The unit may only be used to mix plaster,
investment, and silicon.
• Never connect the paddle without the mixing
bowl.