Fault
Dust is escaping the system.
11 Disassembly
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
► Follow the instructions described in chapters Commissioning and Operation in reverse order to
disassemble and dispose of the device.
6 Commissioning on page EN-11
7 Operation on page EN-16
Dispose of the components in accordance with legal regulations.
12 Disposal on page EN-24
Cause
Filter elements saturated.
Service door not closed.
CAUTION
11 Disassembly
Troubleshooting
► Replace the filter elements.
9.2 Replacing the pre-filter on
page EN-19
9.3 Replacing the primary filter on
page EN-20
► Close the service door.