xFUME™ FLEX
NOTICE
Material damage due to device tipping over
If the extraction arm is protruding when the device is moved, it could cause the device to tip over.
► The device should be moved only when the extraction arm is upright.
NOTICE
Risk of material damage due to improper transport and installation
Improper transport or installation can cause the device to tip or fall over. This can result in material
damage and irreparable damage to the device.
► Protect the device against weather conditions, such as rain and direct sunlight.
► Ensure that the device does not make contact if you pass over edging.
► Use the device only in dry, clean and well-ventilated rooms.
► Maintain a minimum distance of 1 m from the wall when installing the device to ensure that the device
has sufficient ventilation.
► Install the device and lock the castors.
6 Commissioning
Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.
6.1 Mounting the extraction arm
NOTICE
Material damage due to excessive rotation
The extraction arm may become damaged if it is rotated past its limit stop.
► Do not rotate the extraction arm past the limit stop (max. 350°).
Fig. 3
A Extraction hose
B Extraction rod
WARNING
Attaching the extraction hose
A
B
C
D
6 Commissioning
C Connecting tube
D Extraction hood
EN - 11