Place the uncut fibers and maintain the bundle using a piece of hook and loop fastener: (not included)
3M Scotchflex TIE-WRAP code 89839.
Secure uncut fiber bundle in the required area.
Scotchflex
8. Installation of fiber trays
Important notice: There are 2 types of splicing trays. 5mm thick tray can be installed on each position of the holding part.
For the mounting of 10mm trays a free position is required between the backside adjacent cassette and the 10mm cassette.
Max. Capacity:
4x 5mm cassette
2x 5mm and 1x 10mm
2x 10mm
Start mounting the first tray in the box on the slack storage area side.
The back of the splice tray should face the slack storage area.
Leave a free position when using a 10mm thick tray.
5mm thick splice tray
2
4
Position the tray in front of the hinge support and click it (Pic 7-8).
Removing the splice tray: Push the plastic lever and pull the tray out (Pic 9).
Clip colored and numbered ID tags on the tray's corner Identification holders (Pic 10A) and/or use adhesive labels in the
center of the tray (Pic 10B).
7
1
3
8
Retention
parts
10mm thick splice tray
1
2
9
10A
4
1
2
10B