Replacing Parts/ Replacing Main Filter; Replacing Parts/ Replacing The Optional (Upstream) Hepa Filter - Nilfisk cfm A15EXP Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REPLACING PARTS
REPLACING THE OPTIONAL (UPSTREAM) HEPA FILTER
1. Release the latches and remove the Venturi power-head
2. Separate disc "A" from gasket "B" and remove
disc/filter assembly from the vacuum machine.
3. Loosen nut "C" and remove the HEPA filter "D".
4. Fit a new HEPA Filter onto Disc"A" and tighten
in place.
5. Slide the disc with new filter into gasket "B".
6. Replace the suction unit onto the vacuum machine.
7. Dispose of the old filter in accordance with all
federal, state and local regulations.
POS.
N^CODE
1
Z8 33323G
2
Z8 17262
INSTRUCTION FOR USE
Q
DESCRIPTION
1
DISC
1
HEPA FILTER
1
2
3
4
POS.
N^CODE
3
ZBRO10X
ZBDN10X
4
PAGE 7
Q
DESCRIPTION
1
WASHER
1
NUT

Publicité