20
Do not use pump at outside temperatures over 40 °C
or under 0 °C
In cold weather, the pumping body motor should not
bewrapped in a blanket or another piece of textile
with intent toprevent the water freezing.
The user is responsible to third parties if pump (dum-
ping stations, etc.) is used.
Requirements for operating staff 
The operating staff must carefully read the Opera-
ting Instructions before using the appliance.
Qualification:  Apart from the detailed instructions
by a professional, no special qualification is necessary
for appliance using.
Minimum age:  Persons over 16 years of age can
only work on the appliance. An exception includes
youngsters trained in order to reach knowledge
under supervision of the trainer during occupational
education.
Training:  Using the appliance only requires corre-
sponding training by a professional or the Operating
Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. For the sake of eventual
accident, in accordance with DIN 13164, a workplace
has to be fitted with a first-aid kit. It is essential to
replace any used material in the first-aid kit immedia-
tely after it has been used. If you seek help, state the
following pieces of information:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
Maintenance
Before carrying out any work on the machine,
disconnect the plug from the socket.
Prior to every use, visually check the machine to rule
out any defects, in particular on the power cable and
the plug.
The machine must not be used under any circum-
stances if the machine or the safety devices are
damaged.
GP 600 VF P | GP 1100VF | HWA 800 VF P | HWA 1100 VF | HWW 600 VF P | HWW 1100 VF | HWW 1400 VF / INOX
Refer all servicing to customer service. Use only origi-
nal accessories and original spare parts.
Caution: Standing water may corrode (brownish
colour) in the pump according to design.
At winter storing, it is necessary to make sure there is
no water in the appliance as the frost could damage
the appliance. Prior to transportation, it is necessary
to unplug the pump from the grid! The device has to
be completely emptied and stored with frost-proof
protection. Adhesion of mechanical seals can be
prevented if you rinse the pump with appropriate oil
(for example, with vegetable oil).
Only a regularly maintained and treated appliance
can serve as a satisfactory aid. Insufficient mainte-
nance and care can lead to unforeseen accidents and
injuries.
Guarantee
Guarantee claims as per guarantee card attached.
The guarantee solely covers inadequacies caused
by material defect or manufacturing defect. Original
payment voucher with the sales date needs to be sub-
mitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised
use such as appliance overloading, use of violence,
damage as a result of any unauthorised interference
or caused by foreign items. Failing to follow the ope-
rating and assembly instructions and common wear
are also not included in the guarantee..
GÜDE cannot be held responsible for damages
incurred in consequence of unqualified installation or
unskilled handling of the pump.
The device has to be checked on a regular basis to
ensure perfect functioning.
Let us refer to the fact we do not assume any respon-
sibility – according to standards in force – for damage
eventually caused by our appliances in the below-
mentioned cases:
• Unprofessional repairs executed by unauthorised
service centres;
• Use in conflict with the designed purpose, or failure
to observe the use as designed;
• Pump overload with a continuous run;
• Damage as a result of icing or any other fault caused
by climatic influences;
Identical regulations apply for accessory parts.
To prevent damage (such as flooded rooms, etc.) as a
result of faulty pump operation (failure or fault) the ow-
ner (user) is obliged to take reasonable safety measures
(alarm assembly, spare pump, etc.).