Trigger (Tkrs 31 Only); Trigger Plug - SKF TKRS 21 Mode D'emploi

Masquer les pouces Voir aussi pour TKRS 21:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

No laser signal
If no laser signal is found, dash sign indicate the missing signal and
stroboscope is not lashing.

Trigger (TKRS 31 only)

4.3
The device has the option of being externally triggered.
Do not trigger the device with signals in excess of 300 000 FPM.
The stroboscope has the capability to be triggered by an external signal and
to send the current lash rate as a signal to an external device.

4.3.1 Trigger plug

The stroboscope is supplied with a connector that can be used to connect an
external trigger source or signal receiver.
Fig. 8 – Trigger plug
The trigger input and output operates with a NPN bipolar transistor.
W A R N I N G :
Do not exceed the voltage or amperage limits.
W A R N I N G :
Ensure safe cable management when using a trigger cable while operating in
the proximity of moving machines.
EN
15

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Tkrs 31

Table des Matières