SPIDO COMBO-S1 Manuel Utilisateur page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
your pool with water. Ensure that the
water level is at least 2,5 - 5 cm above
the top of the hose intake
(Skimmer) and return ports in the pool.
• The filter system is now vented. If
applicable, open the vent screw on
the upper side of the transparent filter
cover until the water flows out.
• Release the shut off valve at the
intake port (Skimmer) in the pool. If
you plugged the intake port (Skimmer),
remove the plug to allow the water to
flow into the intake hose.
• With
the
filter-pump
installed in a location level lower than
your pool's water level - water will
automatically flow into the pump-filter
system.
• Allow the filter tank to fill with water.
• Check the filter system and the
connection hoses for leaks and
resolve,
if
necessary.
points may possibly arise due to
manufacturing tolerances, which need
to be resolved by wrapping teflon tape
around the connections before the
connection hose is attached.
• Your filter system is now ready for use.
Cleaning the filter balls
The filter balls in the filter tank ensure
that dirt particles and floating debris
are effectively filtered over a long
period of time.
The filter system will reduce its level
of performance in accordance with
the amount of contamination in the
water. This must be checked at regular
intervals.
If you establish that performance
levels are decreasing, please follow
one of these two options:
A: Replace the filter balls.
B: Wash the filter balls in a washing
machine at a maximum temperature
of 30°C.
Filtering time
The swimming pool's water should be
circulated and filtered al least 3 to 5
limes in a 24 hour period, depending
on the load and the size of the tiller
system. The time required is based on
system
the performance of the filter system
and the size of the swimming pool.
However, we recommend a minimum
running lime of 12 hours per day.
POWER SOURCE
INSTRUCTIONS
The filter system you have purchased
is equipped with a connection cable,
Leakage
which may only be connected to a
circuit with a residual current circuit
breaker (RCCB) with a rated residual
current of no more than 30mA.
Technical data:
• Circulation power 2,800 I/h
• Pump is no! self-priming
• maximum water temperature 35 °C
• 230V /100W
• Tank 0 200 mm
• Connector 0 32/38 mm
• Ground plate
• 320g of filter balls are required