INSTALLATION
The manufacturers have no obligation to carry
this out. If the assistance of the manufacturer
is required to rectify faults arising from
incorrect installation, this assistance is not
covered by the guarantee.
Z
X
The installation instructions for
professionally qualified personnel must
be followed.
Z
X
Incorrect installation may cause harm
or injury to people, animals or belongings.
Z
X
The manufacturer cannot be held
responsible for such harm or injury.
Z
X
The oven can be located high in a column
or under a worktop.
Z
X
Before fixing, you must ensure good
ventilation in the oven space to allow proper
circulation of the fresh air required for
cooling and protecting the internal parts.
Z
X
Make the openings specified on last page
according to the type of fitting.
Electrical connection
Z
X
ENSURE THAT AN ELECTRICIAN
OR QUALIFIED TECHNICIAN MAKES
THE ELECTRICAL CONNECTIONS.
Z
X
The power supply to which the oven
is connected must conform with the laws
in force in the country of installation.
Z
X
The manufacturer accepts no responsibility
for any damage caused by the failure
to observe these instructions.
Z
X
The oven must be connected
to an electrical supply with an earthed
wall outlet or a disconnector with multiple
poles, depending on the laws in force
in the country of installation.
Z
X
The electrical supply should be protected
with suitable fuses and the cables used
must have a transverse section that can
ensure correct supply to the oven.
Connection
Z
X
The oven is supplied with a power
cable that should only be connected
to an electrical supply with 220-240 V,
50-60 Hz power between the phases
or between the phase and neutral.
SM 86 P
Before the oven is connected to the electrical
supply, it is important to check:
9 power voltage indicated on the gauge;
9 the setting of the disconnector.
Z
X
The grounding wire connected to the oven's
earth terminal must be connected
to the earth terminal of the power supply.
WARNING! Before connecting
the oven to the power supply, ask a qualified
electrician to check the continuity of the power
supply's earth terminal. The manufacturer
accepts no responsibility for any accidents
or other problems caused by failure to connect
the oven to the earth terminal or by an earth
connection that has defective continuity.
Note: as the oven could require maintenance
work, it is advisable to keep another wall
socket available so that the oven can
be connected to this if it is removed from
the space in which it is installed. The power
cable must only be substituted by technical
service staff or by technicians with equivalent
qualifications.
Switching on the first time
Preliminary cleaning
X
X
Clean the oven before using for the first time.
X
X
Wipe over external surfaces with a damp
soft cloth.
X
X
Wash all accessories and wipe inside
the oven with a solution of hot water and
washing up liquid.
X
X
Set the empty oven to the maximum
temperature and leave on for about 1 hour,
this will remove any lingering smells
of newness.
– 9 –
EN