Alarm Indications - Cardin Elettronica SL Serie Mode D'emploi

Masquer les pouces Voir aussi pour SL Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INDICATIONS ON THE DISPLAY (FIG. 3, PAGE 4)
Start up display
(Shown for 2 seconds)
"424" = programmer model; " _15" = firmware ver-
sion
Indicates the dip-switch setting memorisation stage
and the firmware version

Alarm indications

System not programmed
You have to enter the programming mode to program the
system
Out of position
During normal operation it indicates that the "automatic reposition-
ing" procedure is about to take place (see page 19). In this case any
commands received (TA, TC, TAL or TD) will automatically start this
procedure.
Caution! The gate moves automatically without waiting for
a command.
Memory parameter error
Carries on with the system programming and if the error remains it will
switch off the battery and mains power and reset the programmer. If
the error persists contact the after sales service.
block during programming
This happens when an N.C. contact is activated (Tb, FTCI, FTCS/
CSP) during encoder programming or automatic repositioning. Once
the passive state of the security devices has been reset the gate will
start moving again automatically. It also happens if a blackout occurs
during programming.
Motor feed error
This occurs when the programmer sends a command to the motor and
nothing happens (the motor doesn't move). Check the motor faston
connections and the condition of the fuses "F1", "F3", "F4" and then
give another opening or closing command. If the motor still doesn't
move you are faced with either a mechanical problem or a problem
with the programmer.
Encoder count error
This error normally appears when you have given a command and the
motor is released. If it occurs during normal motor operation it means
that there is a problem with one of the encoder signals. Check the
relative connections and carry out automatic repositioning (pag. 19).
Encoder direction error
The gate movement direction is different from the encoder setting (eg.
the gate moves in the closing direction while the program is carrying
out the opening stage). Check the motor power supply connections.
Current sensor error
When the gate is not moving this symbol means there is a problem
with the current sensor.
Motor error
These symbols mean there is a problem with the motor control
relays
Operational indications
Pause time programming
Automatic programming under way
Serial line (CSER) active
(only for diagnostics)
Opening stage
block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating (only during programming)
Opening + compensation sensor
Closing + compensation sensor
Test mode
battery mode with a fully charged battery
battery mode with an undercharged battery
Discharged battery
When the battery is almost completely flat the symbol
appear on the display and the motor and commands will be
blocked.
22