Terminal board connection
1-2
Programmer power supply 230 Vac
3-4
Transformer power output 230 Vac
5
Programmer power supply earth wire
5
Motor earth wire
7
Tb (NC contact) Stop button input (The opening of this con-
tact interrupts the cycle until a new movement command is
given).
8
Common for all inputs and outputs.
FTCS (NC contact) Safety and control devices in input (stop
9
photoelectric cells). The opening of this contact will block all
movement, until the obstruction has been removed, due to the
safety device cutting in, the gate will then continue moving until
it reaches a travel limit (only in the automatic mode).
CSP (NC contact) Safety buffer input). Opening this contact
will provoke a travel direction inversion of 10 cm, a pause of
3 minutes, after which the motor will continue moving in the
original direction after a 10 second preflashing period has
elapsed.
FTCI (NC contact) Safety and control devices in input (photocells
10
invert the travel direction when an obstruction is detected).
Opening this contact will provoke a travel direction inversion
during closure due to the cutting in of the safety device.
11
Common for all inputs and outputs.
12
30 Vdc output, powering controlled external loads
13
LP 30 Vdc output for warning lights.
25 W intermittent activation (50%), 12,5 W continuous activa-
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
tion.
14
Common for all inputs and outputs.
15
LS 30 Vdc 3W output for an indicator light.
16
Common for all inputs and outputs.
30 Vdc output, powering permanent external loads
17
18
Common for all inputs and outputs.
19
TA (NO contact) Opening button input.
20
Common for all inputs and outputs.
TC (NO contact) Closing button input.
21
22
TD (NO contact) Dynamic button input.
23
Common for all inputs and outputs.
TAL (NO contact) Limited opening button input.
24
L
230Vac
N
TRF 230Vac
L1
CTRL
30Vdc
7
8
9
10
11
12
13
19
20
21
22
23
24
b1
Signal buzzer "via radio" mode
CN1
Motor Faston connection
CSER Serial line connection (only for diagnostics)
D1
Six-segment LED display
S1
Selection dip-switch
E1
Encoder connection
F1
1.6A delayed fuse (230 Vac motor power protection)
F2
3.15A rapid fuse (24V transformer power protection)
F3
10A rapid fuse (motor power protection from the transformer)
.
(1)
.
(1)
L4
M1
OUT
30Vdc
14
15
16
17
18
25 26 27
TRANSFORMER
25
EMRG 1 (NO contact) emergency manoeuvring button input 1
26
EMRG 2 (NO contact) emergency manoeuvring button input 2
27
Common for both emergency buttons.
28
Outer conductor for the radio receiver antenna
29
Inner conductor for the radio receiver antenna (if an external
antenna is fitted use a coaxial type cable RG58 with an imped-
ance of 50Ω).
Note
(
)
The total of the 2 external device outputs must not exceed
1
10W.
ALL UNUSED NC CONTACTS MUST bE JUMPED.
Switch on the power and make sure that the indicator LEDS are in the
following condition (note: If the display is off you can press the PROG
key to show the status of the safety devices.
- L1 Power on
- L2 Wrong battery connection
- L3 Transmitter code programming indicator
- L4 Battery charging
- L5 Indicator for the blocking button "Tb"
- L6 Indicator for the inverting photoelectric cells "FTCI" ON
- L7 Indicator for the stop photoelectric cells "FTCS"
or a contact safety edge "CSP"
- L8 Indicator for the opening button "TA"
- L9 Indicator for the opening button "TC"
- L10 Indicator for the limited opening button "TAL"
- L11 Indicator for the dynamic button "TD/CH1"
Note
If this LED is "on" disconnect the battery power cables imme-
(1)
diately and contact the after sales service.
Note
This LED is "on" when the battery is charged.
(2)
Note
Check that the activation of the safety devices switches the
(3)
corresponding LEDS off.
If the green power on LED "L1" doesn't light up check the condi-
tion of the fuses and the power cable connection at the transformer
primary.
If one or more of the safety LEDS do not light up check the contacts
of the relative security devices and check that the unused safety device
contacts have been bridged.
R1
b1
J1
J2
F5 F3.15A
F4 F10A
J3
CN1
M
L2
F4
10A rapid fuse (battery powered operation motor protection)
F5
3.15A rapid fuse (24V battery powered operation protection)
J1
Radio channel selection
J2
Enable transmitter memorisation via radio
M1
Transmitter code memory module
P1
Programming button (MEMO)
P2
Transmitter code memorization button (DEL)
P3
Transmitter code cancellation button (PROG)
R1
Radio frequency module, 433 MHz for S449 transmitters
17
CS1206.01B DC0398
L5
L8
L10
L6
L9
L7
L11
P1
L3
E1
S1
ON
OFF
(1)
OFF
OFF
(2)
ON
(3)
(3)
ON
(3)
OFF
OFF
OFF
OFF
D1
CSER
P2
P3