PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
• Caution! The installation of both anti-derailment buffers is absolutely obligatory before starting programming.
• Make sure that the safety devices are at rest and the ECU is receiving mains power otherwise you will not be able to enter
programming.
Caution: If the symbol
after 3 minutes has passed since the program-
mer was powered up, the gate will start moving
automatically (after the warning lights have flashed
for 10 seconds) to the completely closed position
(automatic repositioning).
Dip-switch settings S1
Sequential command TD/CH1
Dip 1 "ON" = Sequential command "open-close"
Travel direction inversion only during closing.
Dip 1 "OFF" = Sequential command "open-block-close-block"
Automatic reclosing (DIP 2)
Dip 2 "ON" = Automatic reclosing enabled
Dip 2 "OFF" = Automatic reclosing disabled
Pre-flashing (DIP 3)
Dip 3 "ON" = Pre-flashing activated
Dip 3 "OFF" = Pre-flashing excluded
Warning light output (DIP 4)
Dip 4 "ON" = Warning light output intermittent
Dip 4 "OFF" = Warning light output fixed
Indicator light (DIP 5)
Dip 5 "ON" = Indicator light intermittent
Dip 5 "OFF" = Indicator light fixed
*
The indicator light flashes slowly during opening, rapidly during closing;
remains lit when the gate is blocked but not completely closed and is off when
the gate is completely closed.
FTCI (DIP 6)
Dip 6 "ON" = FTCI also active when the gate is blocked
If the photocells are in alarm and the gate is blocked, no movement commands
will be accepted (even opening commands).
Dip 6 "OFF" = FTCI active only during closing
In both cases activating the FTCI safety device during the closing stage will
force travel direction inversion.
FTCS input selection (DIP 7)
Dip 7 "ON" = contact safety edge active (CSP)
Dip 7 "OFF" = stop photoelectric cells active
Set the dip according to the type of security device you have wired to the input
FTCS.
If neither of the security devices are being used, bridge the contact and set the
dip to "OFF".
Motor installation (DIP 8)
Dip 8 "ON" = Right-hand motor installation
Dip 8 "OFF" = Left-hand motor installation
appears on the display
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
*
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE "PAUSE" SYMBOL
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
ATTENTION! IF THE GATE
MOVES IN THE OPENING
DIRECTION DIP 8 HAS BEEN
SET INCORRECTLY. PRESS
"PROG" AGAIN TO CANCEL
THE PROCEDURE , SET DIP
8 CORRECTLY AND REPEAT
THE PROGRAMMING
PROCEDURE.
WHEN THE GATE REACHES THE COMPLETELY CLOSED POSITION IT INVERTS THE
TRAVEL DIRECTION AND AFTER MOVING FOR A FEW CENTIMETRES IT WILL CLOSE
AGAIN TO CONFIRM THE COMPLETELY CLOSED POSITION. IT NOW OPENS FOR
ABOUT 40 CM THEN CLOSES AGAIN AND STOPS 10 CM FROM THE CLOSED
POSITION TO MEASURE THE INERTIA OF THE GATE LEAF IN THE CLOSING
DIRECTION. AT THIS POINT THE OPENING MANOEUVRE WILL START, AT LOW
SPEED, SO AS TO FIND THE COMPLETELY OPEN POSITION; ONCE IT HAS ARRIVED
AT THE COMPLETELY OPEN POSITION, IT INVERTS THE TRAVEL DIRECTION FOR A
FEW CENTIMETRES AND THEN CONTINUES OPENING IN ORDER TO CONFIRM THE
COMPLETELY OPEN POSITION. IT NOW CLOSES FOR ABOUT 40 CM AND THEN
OPENS ONCE AGAIN UNTIL IT REACHES 10 CM FROM THE COMPLETELY OPEN
POSITION WHERE IT MEASURES THE INERTIA OF THE GATE LEAF IN THE OPENING
DIRECTION. FROM THIS MOMENT THE GATE MOVES AT LOW SPEED ONLY WHEN
IT STARTS UP AND WHEN IT IS ABOUT TO STOP.
AFTER HAVING CARRIED OUT THIS SETTING THE GATE WILL CLOSE AGAIN (ABOUT
1 CM FROM THE MECHANICAL TRAVEL BUFFER). THE CONTROL LOGIC WILL THEN
CARRY OUT A COMPLETE OPENING AND CLOSING CYCLE IN ORDER TO
CALIBRATE THE CURRENT SENSOR.
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL
HAVE TO REPEAT THE
PROGRAMMING
PROCEDURE.
ATTENTION! If you change the dip settings during normal operation you
will have to memorise them. When the display is off press the "PROG"
button once. The symbol "diP" will appear on the display confirming
correct memorisation.
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any
eventual increase in effort above the normal operating limits and intervenes
as an additional safety device.
When the sensor intervenes the gate will automatically invert for 5 cm,
both in the closing as well as the opening direction, to free the obstacle
it will then stop for 3 minutes and then continue moving in the original
direction after a 10 second preflashing period has elapsed.
18
1...4... sec.
THE PAUSE TIME COUNT
(MIN. 2 SECONDS; MAX.
PRESS PROG
120 SECDONDS) WILL
START INDICATED BY
THE "PAUSE" SYMBOL
FLASHING ON THE
DISPLAY.
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE GATE
CLOSES SLOWLY IN
ORDER TO FIND THE
COMPLETELY CLOSED
POSITION.
WHEN THE GATE REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE