6.
Help in the case of irregularities
IMPORTANT!
Always disconnect the mains plug before opening the appliance!
Small irregularities are often caused by mistakes made by the user and can be very often remedied by the user himself.
Should it not be possible to eliminate any irregularity you should get in touch with your specialist dealer or directly with the
THOMAS customer service department. In this case have the information to be found on the type shield ready to hand.
Irregularities
Sudden interruption
in operation
Vacuum cleaner does not start
– Radio
– Control cable
Sudden loss
of suction power
7.

Cleaning and servicing

– Regularly remove the dust and dirt collection in the coarse dirt guard.
– Change the cartridge filter at the recommended intervals.
– Change the remote controller batteries after elapse of the stipulated number of working hours.
8.
Disposal
– Used radio receiver units, radio remote controllers and batteries have to be placed separately in a public collection
container or handed to your dealer.
As the final consumer you are statutorily obliged (Battery ordinance) to return all used batteries and rechargea-
bles; they must not be disposed of in the household refuse.
Batteries and rechargeables containing pollutants, for instance, are marked with the symbol on the left.
It refers to the prohibition of the disposal in the household refuse.
The designation under the symbol stands for the heavy metal which is paramount,
Hg
such as Hg = mercury; Cd = cadmium; Pb = lead.
You can hand in used batteries, rechargeables and button cells free of charge either at your municipality's collec-
tion points or anywhere where batteries / rechargeables / button cells are sold. In this way, you both comply with
the statutory obligations and make your own contribution to environmental protection.
– Cut off all mains cable to prevent misuse.
– Other parts of the appliance and packaging material are to be disposed of according to the valid regulations by the
municipal waste disposal company.
18
Possible causes
Appliance has automatically switched off after 15 minutes
vacuuming (safety function!);
appliance also switches off automatically,
possibly when blocked or through overloading
Vacuum cleaner not switched on.
Remote radio controller batteries are empty;
sender in non-reception area;
Inadequate sender performance.
Radio receiver unit not connected.
No signal given to receiver.
Suction hose has not been locked properly in the suction
box
Suction hose buckled;
Secondary air source, for example
has a second open vacuum socket
Cover on one of the air plug boxes
is not closed airtight;
bulky pieces of material in front of
the coarse dirt guard;
Blocked exhaust air openings on the outside
wall on the site (for example by foliage).
Remedy
Switch on again.
Allow motor to cool down, clear any possible
blockage, then switch on again.
Switch on vacuum cleaner.
Change batteries;
change your position in the room;
repeater insert necessary
(special accessory).
Connect up radio receiver unit.
Reprogram the sender. Place the receiver at
least two meters in front of the vacuum cleaner.
Check connection.
Straighten suction hose, eliminate buckling;
close secondary air source;
clean or replace seal;
remove blockage;
remove blockage