● Improper connections for electricity or water sup-
ply, as well as failures (does not meet the operating
parameters) of electricity or water supply system and
other external networks;
● defects resulting from foreign objects inside product
or liquids, (except those provided by the operating in-
structions, insects, and their metabolic products, etc.);
● Improper storage of the product;
● Replacement of the bulbs, fi lters, batteries, fuses,
and glass / porcelain / fabric and manually operated
parts and other extra wear and tear parts or product,
which have their own limited life, due to the natural
wear and tear, or if replacement is by construction and
is not associated with the assembly of the product;
● defects caused by other system, in which the prod-
uct is used as an element of the system.
● defects resulting from failure by not following the
Buyer's Manual as follows.
Operation features humidifi ers, air purifi ers and de-
humidifi ers
1. It is mandatory for operation of ultrasonic humidi-
fi ers use the original (brand) fi lter cartridge for water
softening if applicable by construction. With the fi lter
cartridge it is recommended to use tap water without
treatment or purifi cation. Life of the fi lter cartridge de-
pends on the hardness of the water and can be un-
predictable decrease, resulting in a white precipitate
around the humidifi er and on the membrane of the
humidifi er. To reduce the likelihood of occurrence of
such sediment fi lter cartridge requires periodic timely
replacement. Service life of fi lters in humidifi ers can
decrease performance out moisture in time, which
requires regular periodic replacement of fi lters accord-
ing to the instructions. For any and all listed in this
paragraph and above faults
damage by the Buyer or a third party, the Seller, or-
ganization designated by the manufacturer, importer,
manufacturer are not liable and the real guarantee for
such problems humidifi ers are not covered.
For operating the product is recommended to use
only the original (branded) accessories of manufac-
turer.
If a humidifi er does not have a fi lter cartridge, it is
recommended to use distilled or softened water. This
will reduce calcium build-up on the membrane. Cal-
cium build-up on the membrane can lead to lower ef-
fi ciency and product malfunction and is not covered by
warranty.
2. Before to start use the air cleaner, take out fi lter
from the bag. For a normal distribution of purifi ed air in
the room do not install an air cleaner in the air fl ow (in
the draft, the fan, etc.). Any damage of the fi lter may
reduce the effectiveness of air purifi cation. Accumu-
lated on the fi lter dust can be carefully removed with
a vacuum cleaner. Water wash of the air cleaner fi lter
is not allowed.
which caused defects,
3. To prevent water leaks and excessive noise, it is
recommended to install the dehumidifi er on a fl at sur-
face. To ensure effi cient drainage, close windows and
doors of the room where is dehumidifi er working. When
moved particularly careful: do not hit the unit, do not tilt
or allow it to fall. Before switching on, make sure that
the condensate tank is installed correctly.
Guide to care for an air conditioning:
1. At least once in 2 weeks, and if necessary, more
frequently, clean the air fi lters inside the unit (check the
Manual). The protective properties of the fi lters based
on electrostatic effect, so even with a slight contamina-
tion, the fi lter does not operate as well.
2. At least once a year, clean the heat exchanger in-
side the unit. To do this: Open the front framework, take
out the air fi lter and by using a vacuum cleaner or a
brush with long bristles gently clean the ribs of the heat
exchanger (note: crushed ribs reduce the effi ciency of
the air conditioner.)
When you do this, be careful not to hurt your hands
by the sharp edges of the ribs!
3. Once a year (better in spring), when necessary,
clean the heat exchanger of the outdoor unit and check
the air conditioner how it works in all modes. This will
ensure reliable operation of your air conditioner.
4. Please remember that the operation of the air con-
ditioner in the winter time has a number of features.
At fi rst, at very low temperatures: -10° C or below for
non-inverter air conditioners and -15° C and below, for
inverter air conditioners, it is recommended to use the
air conditioning only in the ventilation mode. To use the
air conditioner for cooling or heating can be a reason
of malfunction of the air conditioner and compressor
failure. Second, if the outside temperature is negative,
and the condensate (water from the indoor unit) is out-
put outside, it may freeze drain pipe and water, having
no outlet, will fl ow from the indoor unit to the room.
Buyer-Consumer is warned that, by paragraph 11
"List of non-food products of good quality, are not
subject to return or exchange for a similar product of
a different size, shape, size, style, color or confi gura-
tion" Post. Government of the Russian Federation of
19.01.1998. № 55, he has no right to require the ex-
change of products purchased in the order of art. 25 of
the Law "On Protection of Consumer Rights" ist. 502 of
the Civil Code.
Since the signing by the Buyer of the warranty card
is considered that:
● All information about the product and its consumer
properties provided to Buyer fully, in accordance with
Article 10 of the Law "On Protection of Consumer
Rights";
● The Buyer has read and agrees to the terms of the
warranty service and features operation of the product;
● The buyer does not have claims to the appearance
and completeness of the product.
25