C1448, C1848, C2148W
Air and Water Cooled User Manual
Installation: Product Specifications
Location Limitations: The product is designed to be
installed indoors, in a controlled environment. Air
cooled models discharge very warm air into the
room out the back. Space must be allowed at the
left side and back for air intake and discharge.
Water cooled models discharge warm water into
the building's drain. Space needs to be provided on
both sides and above for service access.
Space Limitations
Note: Although the machine will function, ice
capacity of air cooled machines will be significantly
reduced with minimal clearance at the sides, back
and top. Some space is recommended for service
and maintenance purposes on all models.
6" of space at the sides and back are required for
adequate operation. To get the most capacity,
locate the machine away from heat producing
appliances and heating ducts. Provide several feet
of space to the left for maximum ice capacity.
Walls or other large machines near to the ice
machine might also cause a reduction in ice
capacity. One foot behind and two feet above will
be required to make rated capacity.
Airflow is in the front, in the left side, out the back
(as viewed from the front).
Airflow Direction
Environmental Limitations
Air temperature
Water
temperature
Water pressure
Power supply – acceptable voltage ranges
230 volt model
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
November 2006
Page 2
Minimum
Maximum
o
o
10
C.
40
C.
o
o
4
C.
40
C.
1 bar
5 bar
Minimum
Maximum
207 volts
253 volts