6159930390_05
● When you want to change the parameter,
press OK. The value will switch to red.
● Change the values by using left / right buttons
and press OK to validate. Values are coloured
in white.
● When changes are all made in the selected
Pset, you have to save the new values.
Pressing the trigger at that stage will
cancel all modifications done.
● Go to the screen "Exit" at the end of the Pset
parameters list and press OK. Then use
the left / right buttons to select one of the
following:
Press OK: data are saved.
Press OK: data are not saved.
If no action is done, the display returns
to the Pset screen after 15 seconds
and your changes will not be saved.
HOW TO RUN A PSET
● Press the trigger: the tool will run the Pset.
TIGHTENING STATUS & LED REPORTING
The tightening strategy is "Torque
control with angle monitoring".
(Nm)
Max torque
Target torque
Min torque
Downshift torque
Start torque
Min.
Min.
OK
Max.
Angle start
Min
Max
angle
angle
Torque
OK
Max.
Examples:
- Both torque & angle within tolerances will lead
to a green LED reporting + backlight.
- Torque within tolerances + angle below
tolerances will lead to red + yellow status (red
backlight).
When out of tolerances, a voice
message is heard:
- torque error
- angle error
- torque & angle error
For high torque tools running in
severe applications, it may happen
that reports are null when the battery
is low.
HOW TO REVERSE
When you need to free the assembly,
use the Reverse button. LEDs will
alternatively blink red and green.
● Press the trigger.
When delivered, this function is
disabled.
● Go to the "Configuration" menu and press OK.
Then go to "Reverse" and press OK.
● Press OK again to turn "Enable" red. Use the
right button to enable the function and the left
button to disable the function. Press OK to
validate.
● Do the same to select "Alternate" or "Once".
- alternate: the tool will run in reverse
until the operator presses the
Reverse button once again.
- once: the tool will reverse only
once. To run the tool in reverse
again, the operator will press the
Reverse button.
ERGOSTOP
This function allows a smoother tool stop to
reduce the torque reaction on the operator.
(°)
When delivered, this function is disabled.
The Ergostop function must be disabled
for tightening tests or certification on
tightening benches.
26 / 108
26 / 108
English
04/2014
04/2014