Emergency Situations; After-Sales Service; Dismantling And Disposal - Costan VELVET Instructions Pour L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante

11. EMERGENCY SITUATIONS

1) The cabinet will not start or will not keep on working:
• there may be a general blackout;
• the wall main switch may be off;
• the plug of the appliance may be out of the socket.
If power failure is not due to any of the above causes, call the nearest after-sales service
immediately, empty the showcase and store the foods in coldrooms or refrigerators that
may ensure their preservation temperature.
2) The showcase will not cool properly
• the condenser may be dirty and therefore unable to exchange heat. If it is obstructed with dust
or dirt, clean thoroughly as explained in section 10;
• make sure that the product load is correct (see section 7);
• if the showcase has not been defrosted for longer than 3 months, defrost and clean it before
starting normal operation (see section 10, item 4);
• make sure that the case is not exposed to sources of heat or draught;
• make certain that ambient conditions comply with the requirements of page 21, table II;
• check that the showcase is perfectly horizontal by the use of a spirit level.
Should insufficient cooling persist, resort to the nearest after-sales service.
IN CASE OF A GAS LEAK OR FIRE, do not breathe inside the room that houses the cabinet before
having aired it properly. Turn the cabinet off by the main switch ahead (see fig. 23). DO NOT USE
WATER BUT ONLY DRY EXTINGUISHERS TO PUT OUT THE FIRE.
3) The cabinet operates noisily:
• make sure that screws and bolts are securely closed;
• check that the showcase is perfectly horizontal by the use of a spirit level.
Should the inconvenience persist, resort to the nearest after-sales service.

12. AFTER-SALES SERVICE

Should it be necessary to resort to technical assistance, contact your sales person immediately. If
spare parts are needed, always refer to your after-sales service: insist on the use of original spare
parts. Scroll the Italian and European network of branch offices on the back of this manual for ad-
dresses and phone numbers.

13. DISMANTLING AND DISPOSAL

For the sake of the environment, please sort the parts and materials composing the cabinet in ac-
cordance with the waste disposal provisions in force in your country, so that they can be properly
disposed of or recycled. All its parts cannot be treated as solid urban waste, except for the metal
parts, which nevertheless are not considered as special waste by most European countries. THE
PARTS COMPOSING THE REFRIGERATING CIRCUIT MUST NOT BE SEVERED OR SEPARATED BEFO-
RE THE CIRCUIT IS DRAINED WITH RECOVERY OF REFRIGERANT GAS BY QUALIFIED PERSONNEL.
VELCSxx
VELVET
VELNSxx
Epta Spa - Unità locale: Via degli Alpini 14 - 32020 Limana (BL)
ITALIA Tel. 0437/9681 Telefax 0437/967434
45/64
PAGE:
UM000273
N° DOC.

Publicité

Table des Matières
loading

Table des Matières