Diode test
Function
Resistance and Continuity test
Range
Resolution
600.0
0.1
6.000k
0.001k
60.00k
0.01k
600.0k
0.1k
6.000M
0.001M
60.00M
0.01M
Frequency (electronic circuits)
Range
40.00Hz  10kHz
Sensitivity: 2Vrms
Frequency (electronic circuits)
Range
60.00Hz
600.0Hz
6.000kHz
60.00kHz
600.0kHz
1.000MHz
Sensitivity: >2Vrms (@ 20%  80% duty cycle) and f<100kHz; >5Vrms (@ 20%  80% duty cycle) and f>100kHz
Duty Cycle
Range
0.1%  99.9%
Pulse frequency range: 40Hz  10kHz, Pulse amplitude: ±5V (100s  100ms)
Capacity
Range
Resolution
60.00nF
0.01nF
600.0nF
0.1nF
6.000F
0.001F
60.00F
0.01F
600.0F
0.1F
6.000mF
0.001mF
Temperature with K-type probe
Range
-40.0°C ÷ 600.0°C
600°C ÷ 1350°C
-40.0°F ÷ 600.0°F
600°F ÷ 2462°F
(*) Instrument accuracy without probe ; Specified accuracy with stable environmental temperature at ±1°C
For long-lasting measurements, reading increases by 2°C
Test current
<1.5mA
Accuracy
(0.8%reading + 10dgt)
(0.8%reading + 5digits)
(2.5%reading + 10dgt)
Resolution
0.01Hz  0.001kHz
Resolution
0.01Hz
0.1Hz
0.001kHz
0.01kHz
0.1kHz
0.001MHz
Resolution
0.1%
Accuracy
(1.5%reading + 20dgt)
(1.2%reading + 8digits)
(1.5%reading + 8digits)
(1.2%reading + 8digits)
(1.5%reading + 8digits)
(2.5%reading + 20dgt)
Resolution
0.1°C
1°C
0.1°F
1°F
EN - 29
Max voltage with open circuit
3.2VDC
Buzzer
<50
Accuracy
(0.5%reading)
Accuracy
(0.09%rdg+5digits)
Accuracy
(1.2%reading + 2digits)
Protection against overcharge
1000VDC/ACrms
Accuracy (*)
(1.5%reading + 3°C)
(1.5%rdg+ 5.4°F)
HT64
Protection against
overcharge
1000VDC/ACrms
Protection against
overcharge
1000VDC/ACrms
Protection against
overcharge
1000VDC/ACrms
Protection against
overcharge
1000VDC/ACrms