Air Pressure Switch - Güde 231/8/24 6TLG Mode D'emploi Original

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Disposal
Instructions for disposal result from icons on the device,
or more precisely, on the package. Description of each
meaning can be found in the "Marking" chapter.
Operating Staff Requirements
The operating staff must thoroughly read the operating
instructions before using the machine.
Qualification
No additional qualification is needed for using the device
apart from detailed training by a person with expert
knowledge.
Minimum Age
The device may only be operated by persons that have
reached 16 years of age.
An exception includes device use by juveniles within job
preparation for purpose of reaching skills under
instructor's supervision.
Training
Appropriate training is only needed for device use. No
special training is necessary.
Transportation and Storage
If the device is stored for a longer period of time it
needs to be thoroughly cleaned and stored so that it
was not accessible to unauthorised persons.
The compressor must never be stored or transported
laying or under pressure!
Pressure in the air jet may be reduced at
compressed air cooling.
Assembly / First Putting into Operation
If the compressor is supplied without wheels assemble it
with a screw wrench according to pic. 2. The sequence of
screws, nuts and washers is evident from pic. 2. In case
of need, a rubber foot also needs to be screwed on.
Jointing materials, such as screws, nuts, etc. are included
in the supply.
Transport stopper of the oil tank needs to be
exchanged for throat for oil adding and correct oil
level needs to be ensured (see the "Handling Throat
for Oil Adding and Oil Level Inspection" chapter)
before putting the compressor into operation)
Check the oil level at every startup!!!
Handling
Pull the connector plug out of socket before
each maintenance, arrangement and adjustment of
the compressor.
Working Pressure Adjustment
The working pressure may be adjusted very easily:
By turning the knob (2) in the + direction the
working pressure increases. By turning the knob
in the – direction the working pressure reduces.
The working pressure may be locked by tightening the
snap ring.
The compressor is equipped with an automatic safety
valve releasing pressure at overpressure. You may
release pressure from the air jet manually by pulling
the valve ring (10).
ATTENTION:
Realise the amount of compressed air you will need from the
device! The pressure itself, however, is NOT decisive for perfect
and sufficient operation. Short switching the compressor on after
a long break without use is common!
Have any repairs executed exclusively at qualified specialists.
Turn the compressor never about the power,
otherwise no discharge of the unit is done. Without
discharge, the electric motor through the back pressure
damage!
Throat for Oil Adding and Oil Level Inspection
Transport stopper needs to be exchanged for throat
for oil adding and correct oil level needs to be ensured
before putting the compressor into operation.
Check the oil level at every startup!!!
Oil change
Since arriving on the piston can chip, it is absolutely
necessary after the first 10 hours of operation to carry out an
oil change. We recommend that you are our compressor
(SKU: 40056). Later, depending on the operation of the
compressor, all 100 to 200 hours of operation an oil change
place. In order to carry out oil changes, open the drain screw
(16) and begin the process of waste oil in a suitable
container.
Observe strictly the rules for disposal of waste oil and
dispose of it properly in a waste oil collection center.
Unscrew the drain screw is now firmly back on and fill oil up
to the mark on the dipstick
In winter we recommend a lubricity oils to start during
the cold season to help!
Air-pressure switch:
The compressor is equipped with an automatic air-pressure
switch that will switch the compressor off after reaching the upper
limit of the operating pressure and switch it on again when air is
needed. Starting pressure of 6,5 bar, max. pressure of 8 bar.
Inspections and Maintenance
Pull the connector plug out of socket before each work on the
machine. If you are not going to use the device for a longer period
of time we recommend dropping a few oil drops at the place of air
filter insertion so that walls of cylinders were lubricated at next
compressor switching on.
Use a damp cloth for cleaning of plastic parts. Do not use
cleaners, solvents or sharp objects.
Clean the air holes and mobile parts with a soft brush off the
settled dust after each use.
Regularly paint all metal parts with oil.
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

71095

Table des Matières