5.9 ANTIFREEZE Menu
ANTIFREEZE
The function automatically rotates the pump if the temperature falls to values close to zero. The water inside the pump
is thus kept moving and slightly heated, thus limiting the risk of the formation of ice.
This function protects the pump, but it cannot generally prevent the formation of ice in the swimming pool or in other
parts of the system.
5.10 ANTI-LOCK Menu
ANTI-LOCK
This function prevents mechanical blocks occurring in the case of long inactivity; it acts by periodically turning the
pump, at a very low speed that does not create a head.
ENGLISH
PARAMETERS
VALUES
Enable
Yes/No
20%-
Speed
100%
Temperature
4°C - 10
°C
(40°F -
50°F)
ATTENTION: The Antifreeze protection works only as long as the system
is regularly powered: with the electric power disconnected or in the
absence of current (even accidental, such as after a blackout) the
protection cannot work. So it is advisable not to leave the system loaded
during periods of inactivity in winter, but empty it accurately.
In cases of long inactivity, it is advised not to disconnect the electric power
to keep the antilock protection active (see the following paragraph).
The intervention of the Antifreeze function turns the pump even if the system
is in STOP status (white led blinking), and is not influenced by the active
operating mode (manual or automatic).
If you want to prevent the Antifreeze function intervening and turning
on the motor, the function must be disabled.
PARAMETERS
VALUES
Enable
Yes/No
ATTENTION: The Antilock protection works only as long as the system is
regularly powered: with the electric power disconnected or in the absence
of current (even accidental, such as if the automatic switches have blown
due to a storm) the protection cannot work.
The intervention of the Antilock function turns the pump even if the system
is in STOP status (white led blinking), and is not influenced by the active
operating mode (manual or automatic).
If you want to prevent the Antilock function intervening and turning
on the motor, the function must be disabled.
69
DESCRIPTION
Enables or disables the function.
Sets the pump rotation speed during the
intervention of Antifreeze.
Sets the Antifreeze intervention temperature.
The temperature sensor is fitted close to the
motor and does not directly feel the water
temperature, but that of the pump motor
assembly. If the pump is in a technical room,
the outdoor temperature may be lower, even
much lower, than the one measured by the
sensor.
DESCRIPTION
Enables or disables the Anti-Lock
When the function is enabled, the pump
performs an unlocking cycle lasting a few
seconds every 23 hours (elapsed without any
start of the pump).
function.