Rapid Changing Of The Setpoint And Of The Pre-Set Parameters; Advanced Use ("Auto" Mode) - DAB E.SWIM Instructions Pour L'installation Et La Maintenance

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

in both cases, the key function ceases, its LED switches off, and the pump stops.
However, if the "Auto" function was active in the background ("Auto" LED lit), it now takes control of the
machine, deciding either to switch off the pump or to switch on with another setpoint, depending on the
programming made. So the pump might not switch off.
It is very easy to stop the pump manually: with the pump running, just:
press "RUN/STOP".
the pump thus stops in any case (*), interrupting all active modes (this means that also "Auto" mode, which may have
been active in the background, switches off); the green running LED
indicating that the system has been disabled.
When "RUN/STOP" is pressed again, the system is re-enabled and everything is restarted; the white LED
with a steady light.
(*) The only exceptions: the Antifreeze and Antilock functions start the pump even if the system is disabled (see
paragraphs 5.9 and 5.10).
After a blackout during operation in Manual mode, the system does not restart unless the SETx key that
was lit had the duration "ENDLESS". In this case, the system restarts with the same setpoint as before.

3.3 Rapid changing of the setpoint and of the pre-set parameters

When the pump is running with a "SETx" key pressed (as described above):
a  "SETx"  key  different  from  the  active  one  (e.g. 
pressing
setpoint of the new key (for the whole respective duration) and the lighting of the LEDs changes accordingly;
instead, by pressing the up arrow and down arrow keys, you can increase of decrease the flow or speed
(setpoint) at which the pump is operating. The setpoint value is shown on the display on the homepage (see
par. 4.4).
The modified value is stored automatically in the same "SETx" key currently selected (the one with the LED lit).
Also if "QuickClean" has been pressed and the pump is running, the setpoint can be changed with the arrow keys as
described above; the new value is saved directly in the "QuickClean" key.
Both a setpoint and an execution time (or duration) are associated with each "SETx" and "QuickClean"
key. Unlike the setpoints, the times cannot be changed with the quick method described above; however,
they can be changed easily (see 5.2 and 5.5).
The factory values are given in chapter 7.

3.4 Advanced use ("Auto" mode)

Auto with Timers
On this machine there is a powerful and sophisticated system of timed starting at different speeds, each with a
different duration, which can be planned as preferred on a weekly basis. A simple setting of the parameters is
sufficient to perform all the desired cycles completely automatically for seven days. This mode is called "Timers". (See
par. 5.6.)
Before enabling the "Timers" mode, the 4 speeds S5-S8 and the control mode (if constant flow or constant speed)
must be programmed from the "Timer Speeds" menu and then the daily and weekly washing cycles from the "Timers"
menu.
Auto with Remote Control
It is also possible to have all the pump starts commanded by an external control unit, connected to the input signals
(described in 2.5).
The speeds are determined either directly by the analog signal if present or by the settings of the 4 speeds X1-X4
programmable from the External Speeds menu.
The external control mode can be enabled, in this case the pump is controlled exclusively by the external contacts
through the control unit or other, or it can be in Override mode that does not completely disable the operation of the
timers but has priority over them: when an input is active it has priority over the programming set on the pump.
External control is disabled by default.
ENGLISH
switches off. The white LED
while 
"SET3",
52
starts to blink,
is  active)  will  perform  the 
"SET1",
is now lit

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E.proE.swim svrs

Table des Matières