Installation and operation
Setting up
• If the smoke detector is mounted on the mounting base and the detector is
engaged, the detector is supplied with voltage and is activated.
• If the smoke detector is removed from the mounting base, the detector is no
longer ready for operation!
Reset to factory setting (radio connection is deactivated)
Press and hold the code button until the red LED flashes (approx. once per second).
Approx. 5 seconds later, the red LED will start flashing rapidly (approx. once in 0,5
seconds). Release the button and a short acoustic signal will sound. The smoke
alarm has successfully left the network and returned to the factory default settings.

Normal operating mode

The red LED light under the cover will flash approx. every 6 minutes in normal
operating mode signalling that the alarm is ready for use.
Option
– 40 –
Electronic test
Perform regular functional tests on your smoke alarm by holding down the test /
stop button (for approx. 5 seconds). The warning tone will sound and the red
'ALARM' LED light will flash. This does not signal that there is smoke in the room but
it is confirmation that the smoke alarm is functioning correctly.
By testing the device electronics, the mute function is automatically
activated for 11 minutes, during which time the LED will flash once every
10 seconds. After this 11-minute period, the detector will automatically
return to normal operating mode, in which the LED will again flash once
approximately every 6 minutes.
Always test the functioning of the smoke alarm after installation.
Additionally, a monthly inspection is recommended.
Installation and operation
– 41 –
GB