7. Connecting wired detectors
Connection of an external contact (zone 1)
Only one NC contact can be connected to terminals 1 and 2
(Reed). The evaluation takes place via the opening detector it-
self.
Connection of external contacts (Zone 2)
You can connect more than one external detector with NC con-
tacts (or NO contacts) to this opening detector. Two or more de-
vices must be serially (parallel) connected. The cable resistance
must not exceed 100 ohm.
Connect the alarm line of the wired detector to „ALARM" (screw
clamp 2 and 3) and the tamper line of the wired detector to
„TAMP" (screw clamp 4 and 5).
Training of external contacts (Zone 2)
The external contacts of the opening detector are trained for an
extra zone of the system Open and close the "TAMP" connection
until successful reception is confirmed.
Using the detector only as radio modules
You can also use this radio magnet contact as a radio module.
 Close the jumper connection LK2 to deactivate the internal
magnet contact.
 Connect the detectors to the reed contacts and remove the
existing wire strap (zone 1).
 Connect the detector as external zone (see above) (zone2).
FUMK50000W/B
E N