UV-C disinfection cabinet, 280 L
1. Instructions for UV-C disinfection cabinet
Warning: harmful ultraviolet radiation! The radiation produced by this lamp causes damage to the
eyes and skin. Installations containing these lamps must be fully shielded!
The purpose of this UV-C disinfection cabinet is to ensure thorough disinfection of non-farm
materials which are brought onto the farm.
This is not an issue for many materials, as many can be disinfected using other disinfectant agents.
It is however a problem for technical and/or electronic devices.
The cabinet is equipped with four UV-C lamps. These emit radiation at 253.7 nm, the ideal
wavelength for disinfecting materials.
When materials are placed in this cabinet for a period of five minutes, they are exposed to this
radiation. This treatment minimises the risk of contamination.
Specifications:
The UV-C disinfection cabinet is equipped with:
-
Four UV-C lamps, TUV 15W G15T8 UV-C Long Life.
-
Reflective walls: these ensure optimum reflection, causing ozone to be released, which has
a disinfectant action.
-
Timer switch: set to 30 minutes as standard. The switch is located to the bottom right on
the front of the cabinet.
-
A transparent sheet of perspex, the only material that the UV-C radiation can penetrate.
NOTE: Do not use plate glass. UV-C radiation cannot penetrate plate glass and so this
cabinet will not operate at maximum efficiency!
Weight: approx. 50 kg
Power supply: 220 V
External dimensions (l x w x h): 102.5 x 60.5 x 84.5
Capacity: 280 litres
2. Tips and recommendations
The following points must be taken into consideration when using the UV-C disinfection cabinet:
-
The lamps are harmful to your health. NOTE: the lamps switch off automatically when the
cabinet is opened.
-
The UV-C disinfection cabinet uses light to disinfect materials. Make sure that the materials
requiring disinfection are positioned in the cabinet in such a way as to ensure that all parts
of the materials are exposed to the radiation. Five minutes of disinfection will suffice.
-
Take care when placing materials on the perspex sheet to prevent the sheet from cracking
or breaking.
-
In order to ensure the highest possible level of disinfection, we recommend that you
replace the lamps once per year. These can be ordered from your supplier.
-
Always transport the disinfection cabinet in an upright position. Protect from shocks during
transport.