Hatco GLO-RAY GR Serie Manuel D'installation Et D'utilisation page 18

Rampes chauffantes à infrarouge
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPTIONS AND ACCESSORIES
Remote Control Enclosure — RMB2 Series
RmB2 Series remote control enclosures allow multiple strip
heaters to be wired to and controlled by a single enclosure. The
total amp draw of all connected strip heaters cannot exceed the
rating of the remote control enclosure. Consult the factory for
information regarding the proper RmB2 Series remote control
enclosure for a specific application. Refer to the Instruction
Sheet included with the enclosure for installation information.
RMB2 Series Dimensions
Width
Width
Models
(A)
(B)
10-1/8"
11"
RmB2-1R
(257 mm)
(279 mm)
13-1/8"
14"
RmB2-2R
(333 mm)
(356 mm)
Top View
A
Front View
B
Dimensions — RmB2s
RMB2 Series Cutout Dimensions
Opening Cutout
Dimensions
Models
(A)
(B)
4-3/4"
10-1/8"
RmB2-1R
(121 mm)
(257 mm)
4-3/4"
13-1/8"
RmB2-2R
(121 mm)
(333 mm)
B
Cutout Dimensions — RmB2s
NOTE: Make sure the width of the cutout does not exceed the
dimension given for each size enclosure.
Height
Depth
(C)
(D)
5-1/2"
4-1/4"
(140 mm)
(109 mm)
(116 mm)
5-1/2"
4-1/4"
(140 mm)
(109 mm)
(116 mm)
Side View
D
C
Screw Hole
Dimensions
(C)
(D)
1-1/8"
2-1/2"
(29 mm)
(64 mm)
(265 mm)
1-1/8"
2-1/2"
(29 mm)
(64 mm)
(341 mm)
C
A
D
E
Infinite Switch
Use the following procedure to install an infinite switch. an
infinite switch needs to be installed into an approved electrical
box/enclosure (not supplied) by a qualified electrician.
ELECTRIC SHOCK HAzARD: Turn OFF power switch,
disconnect unit from power source, and allow unit to cool
before performing any cleaning, adjustments, or maintenance.
Height
(E)
To prevent premature failure of components due to
4-5/8"
excessive heat, remote mounted control switches must be
installed outside the strip heater heat zone.
4-5/8"
1. Verify unit is off and disconnected from the power source.
2. Install the infinite switch. Refer to the wiring diagram for
proper electrical connections. make sure the switch is
installed with the "H1" terminal oriented on top. This will
ensure that the switch functions match the markings on
the switch label.
• Power In: L1 and L2 (for 100V and 120V units, L2 is
neutral)
• To Heating Element: H1 and H2
NOTE: The terminals on the infinite switch are specially
designed, high-temperature rated terminals that do not
require solder connections.
The infinite switch must be installed using the terminals
E
and wires supplied with the switch. Failure to use the
supplied Genuine Hatco Replacement Parts will void all
warranties and may damage the equipment.
(E)
10-7/16"
LOAD
13-7/16"
Infinite Switch Wiring Diagram (rear view)
NOTE: Make sure the switch is installed with the "H1" terminal
oriented on top ("12 o'clock" position), as shown above.
This will ensure that the switch functions match the
markings on the switch label.
Infinite Switch Kit Part Numbers
Part Number
R02.19.160.00
R02.19.018.00
R02.19.017.00
R02.19.019.00
18
English
WARNING
NOTICE
NOTICE
Voltage
100 volt
120 volt
208 volt
240 volt
Form No. GRm-0115
100V
120V
208V
240V
LINE
NEUTRAL
NEUTRAL
208V
240V

Publicité

Chapitres

Table des Matières
loading

Table des Matières